Owner's Manual
E-18 PD-9810
Chapter 4 PARAMETER
Parameter Table
Described below is the contents of the parameter that is set on each program.
• The parameter values can be stored independently for each program. Each parameter for the taper
tack and the straight bar tack is also independently stored.
• The allowable setting range for some parameters may vary from the range specified, depending on
the settings of each other parameters.
• Two kinds of specifications for the taper tack and the straight bar tack are available as to the
machine and a part of parameters vary with the specifications of the connected machines.
When the programmer is connected to the machine with the taper tack
specifications
No. Setting items Setting range Unit Default
00 Sewing speed 1,000
∼
2,200rpm 100 1,800
01 Eyelet pattern 1
∼
612
02 Button hole length (Note 1)
-00:5∼50mm
-01:5
∼
38mm
-02(L1):14
∼
18mm
(L2):18
∼
22mm
(L3):22
∼
26mm
(L4):26
∼
30mm
(L5):28
∼
32mm
(L6):32
∼
36mm
(L7):36
∼
40mm
1 -00:25mm
-01:25mm
-02(L1):16mm
(L2):20mm
(L3):24mm
(L4):28mm
(L5):30mm
(L6):34mm
(L7):38mm
03 Taper length 0
∼
20mm 1 6
04 Offset 0.5
∼
2.0mm 0.1 1.5
05 Stitch pitch 0.5
∼
2.0mm 0.1 1.0