Service manual

HL-5030/5040/5050/5070N SERVICE MANUAL
4-23
3.12 MP Unit (for HL-5050/5070N only)
(1) Disconnect the two connectors.
(2) Remove the MP ground spring.
(3) Remove the two bind B M3x10 and cup S M3x6 Taptite screws.
(4) Remove the MP solenoid holder unit.
Fig. 4-38
(5) Remove the cup S M3x6 Taptite screw, and then open the MP chute ASSY cover.
(6) Remove the paper pick-up roller ASSY from the shaft.
Fig. 4-39
MP ground spring
Paper pick-up roller ASSY
Taptite, cup S M3x6
MP chute ASSY cover
MP sensor harness
Hook
Shaft
Engine PCB
connector
Taptite, bind B
M3x10
MP solenoid holder unit
Taptite, cup S M3x6