Service manual
HL-5030/5040/5050/5070N SERVICE MANUAL
4-19
3.10 Top Cover
(1) Remove the two bind B M4x12 Taptite screws, and then remove the top cover ASSY.
(2) Disconnect the panel PCB harness from the panel PCB ASSY.
Fig. 4-31
(3) Remove the paper stopper and the support flap S from the top cover ASSY.
Fig. 4-32
Paper stopper
Support flap S
Top cover ASSY
Hook
Hook
Hook
Top cover ASSY
Hooks
Taptite, bind B M4x12
Taptite, bind B
M4x12
Panel PCB ASSY
Panel PCB harness
Hook