Service manual
VI-38
ABCDEFGHJ
1
2
3
4
5
6
DOUBLE
PLUG
DOUBLE
PLUG
COOLING FANS
LVPS(100/120V)
(230V)
PL12.1
MCU HL-4200
MCU HL-4200
PL12.1
PL12.1
+3.3VDC
LVPS(100/120V)(230V)
PL12.1
CONTROL
LOGIC
2.9.3 FAN CONTROL
J12
1
30
PWBA HBN DRV
PL12.1
FAN
CONTROL
J42
30
1
VIO VIO
VIO VIO
J50
7
+24VDC
SWITCHED
9
DC COM
(2.1.1)
J137
3
P137
1
YEL YEL
FAN FUSER
PL1.1
1 3
YEL YEL
P137
2
J137
2
MOT
PWBA
HBN DRV
PL12.1
J50
8
J42
27
YEL YEL
J12
4
VIO VIO
FUSER FAN
ON(H) +24VDC
FUSER FAN
STOP
FUSER FAN FAIL
(H) +3.3VDC
FUSER FAN
LOW
+3.3VDC
18
19
FAN
CONTROL
13
12
VIO VIO
VIO VIO
J166
1
3
FAN REAR
PL12.1
J166
2
J165
7
MOT
J61
3 29
YEL YEL
2
VIO VIO
REAR FAN
ON(H) +24VDC
REAR FAN
LOW
REAR FAN FAIL
(H) +3.3VDC
REAR FAN
STOP
J61
2
4
J165
8
6
YEL YEL
YEL YEL
HEAT AIR
2.9.1
EXHAUST AIR
CONTROL
LOGIC
DO-16
FUSER FAN ON
(HIGH SPEED)
DO-17
(LOW SPEED)
DO-13
DO-14
DI-31
DI-30
2.9.6
FUSER FAN
FAIL SIGNAL
2.9.6
REAR FAN
FAIL SIGNAL
1
1
Virtual Line
1
ZN
F5
ZN
E1
COOLING AIR
DC COM
(2.1.1)
+24VDC
(2.1.1)
DO-18
FUSER FAN OFF
REAR FAN ON
(HIGH SPEED)
(LOW SPEED)
DO-15
REAR FAN OFF
2.9 Fusing and Transportation