Service manual

V-55
4.11 Parameter Setting
4.11.1 Parameter setting/display
Function: Setting and displaying parameters held by IOT in NVM
Operation procedure:
1. Enter the Diag. (C/E) mode.
2. Select [CE Maintenance Parameter] with the
and buttons.
3. Press the Form Feed/Set button to advance to setting/display parameter selection in
[CE Maintenance Parameter].
4. Select a setting/display parameter with the
and buttons.
(For the setting/display parameters, refer to the table below.)
5. Press the Form Feed/Set button to display the setting/display parameter.
Example: Scan Regi Tray1 display screen
6. Select setting data from the setting range with the
and buttons.
7. Press the Form Feed/Set button to write the setting data into NVM.
Example: Post-change screen
8. When displaying and setting each life, have the life item displayed and press the
Form Feed/Set button.
Example: Life Fuser display screen
9. Press the Form Feed/Set button to display data (decimal).
Setting/display parameters
Item Range Description
Paper feed direction
registration adjustment
-128 to 127 Sets the paper feed direction
registration
Scan direction registration
adjustment
-128 to 127 Sets the scan direction registration of
Main, Aux 1, Aux 2, MSI, and Dup.
Life counter -- Reads the fuser and printer life
counters.
Scan Regi Tray1
0*
Scan Regi Tray1
6
Life Fuse
r
Reading
Life Fuse
r
6666