Specifications

eVo5MS0711 08/07/2011
WARNINGNOTE
Properlyinstalled,operatedandmaintainedthisappliancewillnotemitfumesintothedwelling.
Occasionalfumesfromdeashingandrefuellingmayoccur.Howeverpersistentfumeemissionis
potentiallydangerousandmustnotbeignored.Iffumeemissiondoespersist,thefollowing
immediateactionsshouldbetaken:
a) Open
doorsandwindowstoventilatetheroom.
b) Letthefiregoout
c) Checkforflueorchimneyblockageandcleanifrequired.
d) Donotattempttorelightthefireuntilthecauseofthefumeemissionhasbeenidentified
andcorrected.Ifnecessaryseekexpertadvice.
The
mostcommoncauseoffumeemissionisfluewayorchimneyblockage.Foryourownsafety
thesemustbekeptcleanatalltimes.
COAlarm
YourinstallershouldhavefittedaCOalarminthesameroomastheappliance.Ifthealarmsounds
unexpectedly,followtheinstructions
givenunder“WarningNote”above.
Useoffireguard
Whenusingthestoveinsituationswherechildren,agedand/orinfirmpersonsarepresenta
fireguardmustbeusedtopreventaccidentalcontactwiththestove.Thefireguardshouldbe
manufacturedinaccordancewithBS8423:2002,Fireguardsforusewithsolidfuelappliances.
Aerosolsprays
Donotuseanaerosolsprayonornearthestovewhenitisalight.
Useofoperatingtools
Alwaysusetheoperatingtoolsprovidedwhenhandlingpartslikelytobehotwhenthestoveisin
use.
ChimneyFires
Ifthechimneyisthoroughlyandregularlyswept,chimney
firesshouldnotoccur.However,ifa
chimneyfiredoesoccurturntheaircontrolsettingtotheminimum,andtightlyclosethedoorsof
thestove.Thisshouldcausethechimneyfiretogooutinwhichcasethecontrolshouldbekeptat
theminimumsettinguntilthe
fireinthestovehasgoneout.Thechimneyandfluewaysshouldthen
becleaned.Ifthechimneyfiredoesnotgooutwhentheaboveactionistakenthenthefirebrigade
shouldbecalledimmediately.
Afterachimneyfire,thechimneyshouldbecarefullyexaminedforanydamage.Expert
advice
shouldbesoughtifnecessary.