Specifications
Appendices 8200 Compressor
Appendix B: Troubleshooting Procedures Installation, Operation, and Service Instruc-
8040353 Brooks Automation
6-4 Revision 108
2) System power ON/
OFF switch (CB1)
remains in the ON
position, but the com-
pressor will not run.
2a) No power coming from
the power source.
2a) Check service fuses, circuit
breakers, and wiring associ-
ated with power source, and
repair as needed.
2b) Incorrect or disconnected
wiring within the compressor.
2b) Check the compressor
against its electrical sche-
matic, Figure 6-1 on page 6-8.
Table 6-1: Compressor Troubleshooting Procedures
Problem Possible Cause Corrective Action