Specifications

Maintenance Procedures 8200 Compressor
Scheduled Maintenance Installation, Operation, and Service Instructions
8040353 Brooks Automation
5-4 Revision 108
To depressurize the adsorber, attach the depressurization fitting (included in the
Installation and Scheduled Maintenance Tool Kit) to the coupling half at either end of the
adsorber and tighten it slowly.
Figure 5-3: Removing the Adsorber from the Compressor
Installing the Compressor Adsorber
1. Install the replacement adsorber as follows:
a. Remove the dust caps from the self-sealing coupling halves at each end
of the replacement adsorber.
b. Write installation date on the adsorber decal.
c. Install the replacement adsorber following the steps for compressor
adsorber removal in reverse order. Use the hardware saved in Step 5 on
Page 5-2.
2. Connect the adsorber to the compressor internal piping. Refer to Figure 5-2 on
page 5-3.
Explosive Pressure
High pressure explosions could cause severe injury and equipment
damage. Appropriately depressurize the adsorber before disposing of it.
Compressor Base