4. Thread input power cable end up through the strain relief into the enclosure.
5. Attach the power conductors onto the appropriate terminals of the terminal
block.
a. For three-phase hookups, attach the three power leads to terminals X, Y
and Z.
b. For single-phase hookups, attach the two power leads to terminals X
and Y. DO NOT USE TERMINAL Z.
6. Tighten all terminals to 18-22 in.-lbs. torque.
7. Tighten down screws on strain relief.
8. Remount the terminal enclosure cover and secure with two screws.
9. Refer to Final Preparation of Compressor on page 4-8 for correct phasing
checkout procedure.
Equipment Damage
To avoid damaging the power cable, ensure that strain relief is tightened
down on the outer insulation of the input power cable, and that the cable
does not slide.
High Voltage
High voltage electric shock could cause severe injury or loss of life.
Ensure that the ground wire is grounded and uninterrupted.