Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Model 1358 Model 1358 Sho-RateTM "50", Size 8, Flow Indicator Model 1358-V Sho-Rate "50" Meter with optional Needle Control Valve
Model 1358 Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012
Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 WARNING Model 1358 WARNING GLASS TUBE EXPLOSION HAZARD GLASS TUBE EXPLOSION HAZARD Plastic protective sleeve must remain over glass tube. Fasten meter windows securely. Do not operate above pressure and temperature limits. Avoid pressure and flow surges. Do not service or repair while pressurized. Read and understand instruction manual. Failure to comply could result in serious personal injury or property damage.
Model 1358 Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Dear Customer, We appreciate this opportunity to service your flow measurement and control requirements with a Brooks Instrument device. Every day, flow customers all over the world turn to Brooks Instrument for solutions to their gas and liquid low-flow applications.
Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Paragraph Number Contents Model 1358 Page Number Section 1 Introduction 1-1 Description ................................................................................................................................. 1-1 1-2 Design features .......................................................................................................................... 1-1 1-3 Specifications ................................
Contents Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Model 1358 THIS PAGE WAS INTENTIONALLY LEFT BLANK ii
Section 1 Introduction Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Model 1358 1-1 Description The Brooks® Sho-Rate “50” Series of low flow indicators provides a costeffective means of flow indication where the accuracy requirements are not severe. Available options include an integral needle control valve as well as flow controllers piped to the inlet or outlet of the meter.
Section 1 Introduction Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Model 1358 Scales Type (Standard): Fused on meter tube Length: 75 mm, nominal Graduations: Standard: direct read on tube in gpm water or scfm air. Optional: special direct read decal on tube. Consult factory for available ranges. Direct read on metal scale plate mounted beside tube.
Section 1 Introduction Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Model 1358 Protective Tube Sleeve UV stabilized polycarbonate ! WARNING GLASS TUBE EXPLOSION HAZARD Plastic protective sleeve must remain over glass tube. (Meter sizes 7 -13 only) Fasten meter windows securely. Do not operate above pressure and temperature limits. Avoid pressure and flow surges. Do not service or repair while pressurized. Read and understand instruction manual.
Section 1 Introduction Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Model 1358 Tube Packing Standard: Neoprene® (Brass meters), Viton-A® fluoroelastomers (316 stainless steel meters).
Section 2 Installation Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Model 1358 2-1 Receipt of Equipment When the instrument is received, the outside packing case should be checked for damage incurred during shipment. If the packing case is damaged, the local carrier should be notified at once regarding his liability. A report should be submitted to your nearest Product Service Department. Brooks Instrument 407 W. Vine Street P.O.
Section 2 Installation Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Model 1358 2-3 Return Shipment Prior to returning any instrument to the factory, contact your nearest Brooks location for a Return Materials Authorization Number (RMA#). This can be obtained from one of the following locations: Brooks Instrument 407 W. Vine Street P.O.
Section 2 Installation Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Model 1358 VERTICAL LINE HORIZONTAL LINE D FLOWMETER B FLOWMETER B A C D A E E C A - Inlet Valve B - Outlet Valve D - Control Valve C - Bypass Valve E - Drain Valve Figure 2-1 Typical Bypass Installation 2-3
Section 2 Installation Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Model 1358 1 1 2 7 16 38.1 1 2 4 1 25.4 57.2 5 8 1 1 2 [38.1] 15.9 11.1 1 1 [27.0] DIA. 16 2 HOLES REQ'D. DIMENSIONS ARE INCH [MM] 1 [25.4] OUTLET 1 [6.4] 4 1 2 12.7 3 1 4 7 8 16 7 [177.8] 44.4 214.3 7 15 2 16 9 177.8 75 NOMINAL SCALE LENGTH 1 5 2 [139.7] 228.6 3 4 4 5 [127.0] 120.6 SAFETY SHIELDS 1 1 4 31.
Section 3 Operation Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Model 1358 3-1 Operating Instructions After the flowmeter has been properly installed in the system, it is ready for operation. ! WARNING GLASS TUBE EXPLOSION HAZARD Plastic protective sleeve must remain over glass tube. (Meter sizes 7 -13 only) Fasten meter windows securely. Do not operate above pressure and temperature limits. Avoid pressure and flow surges.
Section 3 Operation Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Model 1358 Rate of flow is indicated by reading the increments inscribed on the metering tube or direct etched scale parallel with the metering edge of the float. For the correct reading edge of the float, refer to Figure 3-2. ! CAUTION A built-in needle control valve may be provided to control the flow through the flowmeter. These control valves are designed for fine control.
Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Section 4 Maintenance Model 1358 4-1 General Model 1358 flowmeters require little maintenance except routine cleaning. It is necessary to remove the flowmeter from the line for tube and float cleaning. The tube and float may be cleaned with a soft absorbent swab. To disassemble the flowmeter proceed as follows: a. Remove the front and rear window shields. b.
Section 4 Maintenance Model 1358 Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 h. With the metering tube out, the seal spindle or jack screw may be rotated clockwise for removal. It should not be necessary to remove the seal spindle unless the O-ring which seals the spindle requires replacement. The O-ring may be used as long as it is not torn or distorted. i. The needle control valve assembly may be removed by turning the valve body counterclockwise.
Section 5 Parts List Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Model 1358 5-1 General When ordering parts please specify: Brooks Serial Number, Model Number, Part Number, Description and Quantity. Refer to Figures 5-1 and Tables 5-1.
Section 5 Parts List Model 1358 Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Table 5-1 Model 1358 Parts List REF NO 1 2 3 4 5 6 7 8 9 10 11 12 5-2 QTY 1 1 1 1 2 1 1 1 1 1 1 1 DESCRIPTION GLASS METERING TUBE 316 S.S. FLOAT 8-RV-8 8-RJ-10 8-RJ-23 8-RJ-30 8-RJ-39 INLET FLOAT STOP SPRING FLOAT STOP 0.8, 3.5 & 5 GPM SPRING FLOAT STOP 1.5 & 2.5 GPM OUTLET FLOAT STOP SPRING FLOAT STOP 0.8, 3.5 & 5 GPM SPRING FLOAT STOP 1.5 & 2.
Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Section 5 Parts List Model 1358 Table 5-1 Model 1358 Parts List (Continued) 13 14 2 2 15 2 16 1 ADAPTER 3/8" NPT ADAPTER, NO LOCKNUT: 316 SS 3/8" NPT ADAPTER, NO LOCKNUT: BRASS 3/8" NPT ADAPTER, FOR LOCKNUT: 316 SS 3/8" NPT ADAPTER, FOR LOCKNUT: BRASS 1/2" NPT ADAPTER, NO LOCKNUT: 316 SS 1/2" NPT ADAPTER, NO LOCKNUT: BRASS ADAPTER O-RING VITON BUNA-N EPM KALREZ LOCKNUT FOR FRONT OF PANEL MOUNTING 014C023BMA
Section 5 Parts List Model 1358 Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Table 5-1 Model 1358 Parts List (Continued) 31 1 32 1 VALVE BONNET 316 SS BRASS VALVE STEM 33 1 VALVE BACKING O-RING 34 1 950Z067BMA 950Z067GGJ 949Z198BMA 375B011QMA 36 1 REDUCING BUSHING 3/8" NPT TO 1/4" NPT, SS 3/8" NPT TO 1/4" NPT, BRASS 3/8" NPT TO 3/4" NPT, SS WARNING LABEL 37 1 LOGO LABEL 38 1 VALVE PLUG 39 1 014B231BMA 014B231GGA 014B234BMA 502Z969MYA 502C3
Installation and Operation Manual Section A - Essential Instructions X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Bulgarian Ɉɫɧɨɜɧɢ ɢɧɫɬɪɭɤɰɢɢ ɉɪɨɱɟɬɟɬɟ ɩɪɟɞɢ ɪɚɛɨɬɚ! Brooks Instrument ɩɪɨɟɤɬɢɪɚ, ɩɪɨɢɡɜɟɠɞɚ ɢ ɬɟɫɬɜɚ ɩɪɨɞɭɤɬɢɬɟ ɫɢ ɩɨ ɬɚɤɴɜ ɧɚɱɢɧ, ɱɟ ɬɟ ɞɚ ɨɬɝɨɜɚɪɹɬ ɧɚ ɦɧɨɝɨɛɪɨɣɧɢ ɧɚɰɢɨɧɚɥɧɢ ɢ ɦɟɠɞɭɧɚɪɨɞɧɢ ɫɬɚɧɞɚɪɬɢ. Ɍɟɡɢ ɨɛɨɪɭɞɜɚɧɢɹ ɬɪɹɛɜɚ ɩɪɚɜɢɥɧɨ ɞɚ ɫɟ ɢɧɫɬɚɥɢɪɚɬ, ɟɤɫɩɥɨɚɬɢɪɚɬ ɢ ɩɨɞɞɴɪɠɚɬ ɡɚ ɞɚ ɫɟ ɝɚɪɚɧɬɢɪɚ, ɱɟ ɳɟ ɦɨɝɚɬ ɞɚ ɪɚɛɨɬɹɬ ɫɴɨɬɜɟɬɧɨ ɧɚ ɬɟɯɧɢɬɟ ɧɨɪɦɚɥɧɢ ɫɩɟɰɢɮɢɤɚɰɢɢ.
Section A - Essential Instructions Installation and Operation Manual X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Czech Základní instrukce PĜed instalací si pĜeþtČte následující instrukce! Spoleþnost Brooks Instrument konstruuje, vyrábí a testuje tento produkt tak, aby splnil mnoho národních a mezinárodních standardĤ. PĜístroje musí být ĜádnČ nainstalovány, používány a udržovány tak, aby byl zajištČn jejich nepĜetržitý provoz v rámci normálních technických specifikací.
Installation and Operation Manual Section A - Essential Instructions X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Dansk Grundlæggende vejledninger Læs disse før anvendelse! Brooks Instruments designer, fremstiller og afprøver sine produkter således, at de tilpasser sig både de indenrigs og internationale standarder. Disse udstyr bør installeres, bruges og repareres omhyggeligt, så at de kan virke tilsvarende deres normale anvendelsesperiode.
Section A - Essential Instructions Installation and Operation Manual X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Dutch Essentiële instructies Lees ze voordat u verder gaat! Brooks Instrument ontwerpt, produceert en test haar producten zodanig dat ze voldoen aan vele nationale en internationale normen. Deze producten moeten correct worden geïnstalleerd, bediend en onderhouden zodat ze binnen hun normale specificaties blijven werken.
Section A - Essential Instructions Installation and Operation Manual X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Estonian Olulised juhised Enne kasutamist lugege hoolikalt läbi! Brooks Instrument konstrueerib, valmistab ja katsetab oma tooteid selliselt, et need vastaksid paljude erinevate riiklike ja rahvusvaheliste standardite nõuetele. Ainult nõuetekohane paigaldamine, kasutamine ja hooldamine tagab toodete katkematu talitluse tavaspetsifikatsiooni raames.
Section A - Essential Instructions Installation and Operation Manual X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Finnish Perusohjeet Lue ensin ohjeet huolellisesti! Brooks Instrument suunnittelee, valmistaa ja testaa laitteensa vastaamaan useimpien kotimaisten ja kansainvälisten standardien vaatimuksia. Tuotteet tulee asentaa, käyttää ja huoltaa käyttöohjeiden mukaan jotta niiden toimivuus taataan.
Installation and Operation Manual Section A - Essential Instructions X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 French Instructions essentielles A lire avant de commencer ! Brooks Instrument conçoit, fabrique et teste ses produits pour répondre à de nombreuses normes nationales et internationales. Ces produits doivent être correctement installés, utilisés et entretenus pour pouvoir fonctionner dans le cadre de leurs spécifications normales.
Section A - Essential Instructions Installation and Operation Manual X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 German Wichtige Anweisungen Bitte zuerst lesen! Brooks Instrument entwickelt, produziert und testet seine Produkte derart, dass sie viele nationale und internationale Standards erfüllen. Nur bei korrektem Einbau sowie richtiger Bedienung und Wartung dieser Produkte ist ein Betrieb unter Einhaltung der Standardvorgaben sichergestellt.
Installation and Operation Manual Section A - Essential Instructions X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Greek ǺĮıȚțȑȢ ȠįȘȖȓİȢ ǻȚĮȕȐıIJİ ʌȡȚȞ ıȣȞİȤȓıİIJİ! Ǿ Brooks Instrument ıȤİįȚȐȗİȚ, ʌĮȡȐȖİȚ țĮȚ įȠțȚȝȐȗİȚ IJĮ ʌȡȠȧȩȞIJĮ IJȘȢ ıİ ıȣȝȝȩȡijȦıȘ ȝİ ʌȜȒșȠȢ İșȞȚțȫȞ țĮȚ įȚİșȞȫȞ ʌȡȠIJȪʌȦȞ. Ǿ ıȦıIJȒ İȖțĮIJȐıIJĮıȘ, ȤȡȒıȘ țĮȚ ıȣȞIJȒȡȘıȒ IJȠȣȢ ĮʌȠIJİȜİȓ ĮʌĮȡĮȓIJȘIJȘ ʌȡȠȨʌȩșİıȘ IJȘȢ ȜİȚIJȠȣȡȖȓĮȢ İȞIJȩȢ IJȦȞ țĮȞȠȞȚțȫȞ ȠȡȓȦȞ.
Section A - Essential Instructions Installation and Operation Manual X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Hungarian AlapvetĘ utasítások ElĘször olvassa el ezeket! A Brooks Instrument olyan módon tervezi, gyártja és teszteli termékeit, hogy azok megfeleljenek számos belföldi és nemzetközi szabványnak. Ezeket a berendezéseket megfelelĘen kell telepíteni, üzemeltetni és karbantartani ahhoz, hogy mindenképpen a normál mĦködési tartományuknak megfelelĘen üzemelhessenek.
Installation and Operation Manual Section A - Essential Instructions X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Italian Istruzioni fondamentali Leggerle subito! La Brooks Instrument progetta, fabbrica e collauda i propri prodotti in maniera tale che siano conformi ai vari standard nazionali ed internazionali.
Section A - Essential Instructions Installation and Operation Manual X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Latvian SvarƯga instrukcija Pirms turpinƗt izlasiet! „Brooks Instrument” projektƝ, ražo un pƗrbauda savus ražojumus atbilstoši daudziem nacionƗlajiem un starptautiskajiem standartiem. Lai nodrošinƗtu šo izstrƗdƗjumu turpmƗku darbƯbu atbilstoši noteiktajiem parametriem, tie ir pareizi jƗuzstƗda, jƗlieto un jƗapkopj.
Section A - Essential Instructions Installation and Operation Manual X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Lithuanian Pagrindinơs instrukcijos Perskaitykite prieš tĊsdami! „Brooks Instrument“ projektuoja, gamina ir išbando savo gaminius, kad jie atitiktǐ Ƴvairius nacionalinius ir tarptautinius standartus. Šie gaminiai turi bnjti tinkamai montuojami, eksploatuojami ir prižinjrimi, kad ir toliau veiktǐ pagal jiems bnjdingus techninius parametrus.
Section A - Essential Instructions Installation and Operation Manual X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Polish Zalecenia wstĊpne Prosimy przeczytaü przed rozpoczĊciem uĪytkowania! Brooks Instrument projektuje, wytwarza i testuje swoje produkty tak, aby speániaáy wymagania licznych norm krajowych i miĊdzynarodowych. Te produkty muszą byü poprawnie instalowane, obsáugiwane oraz konserwowane, aby zapewniü ich prawidáowe dziaáanie zgodnie ze specyfikacją techniczną.
Installation and Operation Manual Section A - Essential Instructions X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Portuguese Instruções Básicas Ler antes de proceder! A Brooks Instrument projecta, fabrica e testa os seus produtos de forma a satisfazer numerosas normas nacionais e internacionais. Estes equipamentos devem ser instalados, utilizados e mantidos de forma adequada, e devem funcionar dentro da sua gama de utilização.
Section A - Essential Instructions Installation and Operation Manual X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Romanian IndicaĠii de referinĠă CitiĠi-le întâi pe acestea! Brooks Instrument îúi proiectează, produce úi testează produsele într-un mod ce respectă un mare număr de standarde autohtone úi internaĠionale. Aceste instalaĠii trebuie amplasate, exploatate úi întreĠinute corespunzător, pentru ca în toate situaĠiile, domeniul lor de lucru să corespundă operării normale.
Installation and Operation Manual Section A - Essential Instructions X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Slovak Základné príkazy PreþítaĢ pred inštaláciou! Brooks Instrument svoje výrobky projektuje, vyrába a testuje takým spôsobom, aby tieto vyhoveli domácim aj medzinárodným normám. Tieto zariadenia je potrebné predpísaným spôsobom inštalovaĢ, prevádzkovaĢ a udržiavaĢ, na zabezpeþenie ich spoĐahlivej a normálnej prevádzky v celom pracovnom rozsahu.
Section A - Essential Instructions Installation and Operation Manual X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Slovene Osnovna navodila Najprej preberite jih Brooks Instrument tako konstruira, izdeluje in terstira svoje izdelke, da oni ustrezajo številnim domaþim in mednarodnim standardom. Te naprave se morajo ustrezno instalirati, koristiti in vzdrževati, da vsekakor delajo ustrezno normalnom podroþju funkcioniranja.
Section A - Essential Instructions Installation and Operation Manual X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Spanish Instrucciones básicas ¡Léalos primero! El Brooks Instrument proyecta, fabrica y prueba sus productos de manera que éstos respondan a numerosas normas nacionales e internacionales. Dichas instalaciones deben ser emplazadas, operadas y mantenidas adecuadamente, para que puedan marchar de todas formas en conformidad con el alcance normal de funcionamiento.
Section A - Essential Instructions Installation and Operation Manual X-VA-1358-eng Part Number:541B041AAG September, 2012 Model 1358 Swedish Väsentliga anvisningar. Läs detta innan du fortsätter ! Brooks Instrument konstruerar, tillverkar och testar sina produkter med syfte att uppfylla alla nationella och internationella standarder. Dessa produkter måste installeras på rätt sätt, handhas och underhållas för att de skall fungera kontinuerligt enligt deras normala specifikation.
Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 Model 1358 THIS PAGE WAS INTENTIONALLY LEFT BLANK
Model 1358 Installation and Operation Manual X-VA-1358-eng Part Number: 541B041AAG September, 2012 LIMITED WARRANTY Seller warrants that the Goods manufactured by Seller will be free from defects in materials or workmanship under normal use and service and that the Software will execute the programming instructions provided by Seller until the expiration of the earlier of twelve (12) months from the date of initial installation or eighteen (18) months from the date of shipment by Seller.