Product Manual - RFID Reader UF70 Certum 51
Chapter 7
Operation
The use of a defined filter can hereby be enabled or disabled.
Values:
"00" – Filter off
"FF" – Filter on
Displays the current status of the outputs at the corresponding antenna port
(Head ID). The information unit "Output state" includes the status of each output
of an antenna port. In the case of querying the status of all outputs of the reader,
the "Output State" contains the status of all 4 outputs (1 per head). The status is
represented as 1 byte for each head.
Values:
0 – Output OFF
1 – Output ON
2 – Output flashes
3 – unchanged (query only!)
Number of the parameter. Two ASCII characters (2 bytes) display the parameter
number in HEX format.
Example:
Parameter 20 0x14 "14"
Value of the parameter. Two ASCII characters (2 bytes) specify the value of the
parameter in HEX format.
Example:
Value 192 0xC0 "C0"
On/Off 4 bytes
Output state 1 - 4 bytes
Parameter no. 2 bytes
Parameter value 2 bytes