User's Manual
Table Of Contents
- Product Manual RFID Reader UF70 Certum
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Communication protocol ASC-I1
- 7.2.1 Structure of the communication protocol
- 7.2.2 Package contents
- 7.2.3 Commands of protocol
- X or URX - Read data area
- URY - Read data area (defined EPC code)
- M - EPC scanning
- URB - EPC Bulk reading
- W - Write EPC code
- UWW - Write data range of all EPC transponders
- UWZ - Write data range of all EPC- transponders (defined EPC code)
- UMW - Write data range of all EPC transponders masked
- UMZ - Write data range of all EPC- transponders (defined EPC code) masked
- UBW - Erase block of all EPC transponders
- UBZ - Erase block of all EPC transponders (defined EPC code)
- ULW - Locking all EPC transponders
- ULZ - Locking all EPC transponders (defined EPC code)
- UKW - Killing all EPC transponders
- UKZ - Killing all EPC transponders (defined EPC code)
- T and UAM - Enable read polling EPC
- UAA - Enable Read Polling Raw
- UAX - Polling Read Data
- UAW - Polling Write Data
- UAZ - Polling Write Masked Data
- UAB - Erase Block
- UAL - Lock EPC
- UAK - Kill EPC transponder
- UAR - Polling transponder rate
- UAE - End polling
- UCX - Activate polling NXP- UCODE-G2X Read Protect
- UCN - Activate polling NXP- UCODE-G2X Reset Read Protect
- UCC - Activate Polling NXP- UCODE-G2X Change EAS
- UCE - Activate polling NXP- UCODE-G2X EAS alarm
- UFW - Set filter data
- UFR - Read filter data
- UFP - Set filter
- UFG - Read filter data
- UGL - Read list of radio profiles
- UGP - Read active radio profile
- UPP - Set active radio profile
- UNH - Hardware reset
- UNR or N - Software reset
- UPE - Factory Reset/Factory Setting
- F - Parameter query
- P - Set parameter
- N - Reset
- UGK - Determine active parameter set
- UPK - Define the active parameter set
- UGD - Determine default parameter set
- UPD - Define default parameter set
- B - Sensor status
- O - Set output
- Q - Queries of the output status
- E - Error message
- H - Heartbeat
- UVR or V - Query software version
- UGT - Read UTC time
- UPT - Set UTC time
- Sensor triggered automatic reading
- 7.2.4 Parameters
- Parameter 0 (0x00)
- Parameter 01 (0x01)
- Parameter 03 (0x03)
- Parameter 04 (0x04)
- Parameter 06 (0x06)
- Parameter 07 (0x07)
- Parameter 08 (0x08)
- Parameter 11 (0x0B)
- Parameter 12 (0x0C)
- Parameter 20 (0x14)
- Parameter 21 (0x15)
- Parameter 22 (0x16)
- Parameter 23 (0x17)
- Parameter 24 (0x18)
- Parameter 26 (0x1A)
- Parameter 27 (0x1B)
- Parameter 28 (0x1C)
- Parameter 29 (0x1D)
- Parameter 33 (0x21)
- Parameter 34 (0x22)
- Parameter 39 (0x27)
- Parameter 40 (0x28)
- Parameter 41 (0x29)
- Parameter 93 (0x5D)
- Parameter 94 (0x5E)
- Parameter 95 (0x5F)
- Parameter 96 (0x60)
- Parameter 97 (0x61)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- Parameter 100 (0x64)
- Parameter 101 (0x65)
- Parameter 102 (0x66)
- Parameter 103 (0x67)
- Parameter 104 (0x68)
- Parameter 105 (0x69)
- Parameter 106 (0x6A)
- Parameter 107 (0x6B)
- Parameter 108 (0x6C)
- Parameter 109 (0x6D)
- Parameter 110 (0x6E)
- Parameter 111 (0x6F)
- Parameter 112 (0x70)
- Parameter 113 (0x71)
- Parameter 114 (0x72)
- Parameter 115 (0x73)
- Parameter 116 (0x74)
- Parameter 117 (0x75)
- Parameter 118 (0x76)
- Parameter 119 (0x77)
- Parameter 120 (0x78)
- Parameter 121 (0x79)
- Parameter 122 (0x7A)
- Parameter 123 (0x7B)
- Parameter 124 (0x7C)
- Parameter 125 (0x7D)
- Parameter 126 (0x7E)
- Parameter 127 (0x7F)
- Parameter 128 (0x80)
- Parameter 129 (0x81)
- Parameter 130 (0x82)
- Parameter 131 (0x83)
- Parameter 132 (0x84)
- Parameter 133 (0x85)
- Parameter 134 (0x86)
- Parameter 135 (0x87)
- Parameter 136 (0x88)
- Parameter 137 (0x89)
- Parameter 138 (0x8A)
- Parameter 139 (0x8B)
- Parameter 140 (0x8C)
- Parameter 141 (0x8D)
- Parameter 142 (0x8E)
- Parameter 143 (0x8F)
- Parameter 144 (0x90)
- Parameter 145 (0x91)
- Parameter 146 (0x92)
- Parameter 147 (0x93)
- Parameter 148 (0x94)
- Parameter 149 (0x95)
- Parameter 150 (0x96)
- Parameter 151 (0x97)
- Parameter 152 (0x98)
- Parameter 153 (0x99)
- Parameter 154 (0x9A)
- Parameter 155 (0x9B)
- Parameter 156 (0x9C)
- Parameter 157 (0x9D)
- Parameter 158 (0x9E)
- Parameter 159 (0x9F)
- Parameter 160 (0xA0)
- Parameter 161 (0xA1)
- Parameter 162 (0xA2)
- Parameter 163 (0xA3)
- Parameter 164 (0xA4)
- Parameter 165 (0xA5)
- Parameter 166 (0xA6)
- Parameter 167 (0xA7)
- Parameter 168 (0xA8)
- Parameter 169 (0xA9)
- Parameter 170 (0xAA)
- Parameter 171 (0xAB)
- Parameter 172 (0xAC)
- Parameter 173 (0xAD)
- Parameter 174 (0xAE)
- Parameter 175 (0xAF)
- Parameter 176 (0xB0)
- Parameter 177 (0xB1)
- Parameter 178 (0xB2)
- Parameter 179 (0xB3)
- 7.3 Additional information
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- Index
Product Manual - RFID Reader UF70 Certum 48
Chapter 7
Operation
The extension flag determines which information is included in the recognized
EPC transponder. The Ex flag is set by parameter 0x76. The data are interpreted
in HEX format. That is, two ASCII characters in the message equal one byte of
data in HEX format.
Values:
0x00 do not transmit extensions
0x01 only transmit antenna port
0x02 only transmit RSSI value
0x03 transmit antenna port and RSSI
0x04 transmit time stamp
0x05 transmit time stamp and antenna port
0x06 transmit time stamp and RSSI value
0x07 transmit time stamp, RSSI value and antenna port
0x08 transmit transponder protocol control word
0x09 transmit antenna port and transponder protocol control word
0x0A transmit RSSI value and protocol control word
0x0B transmit antenna port, RSSI value and protocol control word
0x0C transmit time stamp and protocol control word
0x0D transmit time stamp, antenna port and protocol control word
0x0E transmit time stamp, RSSI and protocol control word
0x0F transmit time stamp, RSSI, antenna port and protocol control word
If and which extensions are transmitted for each detected EPC transponder is
defined by the Ex flag. The data are interpreted in HEX format. That is, two ASCII
characters in the message equal one byte of data in HEX format. The activated
extensions are transferred in the following order:
2 ASCII characters antenna port
2 ASCII characters RSSI value
8 ASCII characters UTC time stamp (LSB byte is transmitted first)
4 or 8 ASCII character protocol word as applicable including XPC_W1 and
XPC_W2
Ex flag 2 bytes
Extension 0 - 12 bytes