Operation
Parameter 161
(0xA1)
Tag Comm Default Profile
A communication profile includes transmission data rate, reception data rate and
transponder response encoding (FM0, Miller 2, Miller 4, Miller 8) in meaningful
and standard-conforming combinations. The list of supported profiles is available
with the UGL command.
Value range: 0x00 to 0xFF
Default: 0x04
Parameter 162
(0xA2)
RF Interface Multiplexing Exposure Time 1
Dwell time on the antenna port, which is defined as the first list entry of the
multiplexing antenna port list (par. RF Interface Multiplexing Antenna Port 1).
The dwell time indicates how long an inventory is performed on an antenna port
(only for polling actions).
Value range: 0 to 65,535 in ms
Default: 100 ms
Parameter 163
(0xA3)
RF Interface Multiplexing Exposure Time 2
Dwell time on the antenna port, which is defined as the first list entry of the
multiplexing antenna port list (par. RF Interface Multiplexing Antenna Port 2).
The dwell time indicates how long an inventory is performed on an antenna port
(only for polling actions).
Value range: 0 to 65,535 in ms
Default: 100 ms
Parameter 164
(0xA4)
RF Interface Multiplexing Exposure Time 3
Dwell time on the antenna port, which is defined as the first list entry of the
multiplexing antenna port list (par. RF Interface Multiplexing Antenna Port 3).
The dwell time indicates how long an inventory is performed on an antenna port
(only for polling actions).
Value range: 0 to 65,535 in ms
Default: 100 ms