User's Manual

Table Of Contents
Product Manual - RFID Reader UF70 Certum 144
Chapter 7
Operation
Parameter 138
(0x8A)
RF Interface Multiplexing Antenna Port 2
Second list entry of the antenna port list!
The multiplexing antenna port list specifies the order of the antenna ports for a
multiple antenna inventory. The dwell time of the inventory corresponding with
the list entry is defined later by the parameter "Interface Multiplexing Exposure
Time 2".
Value range:
0x00 no antenna port
0x01 to 0x04 for the respective antenna port
Default: 0x02
Parameter 139
(0x8B)
RF Interface Multiplexing Antenna Port 3
Third list entry of the antenna port list!
The multiplexing antenna port list specifies the order of the antenna ports for a
multiple antenna inventory. The dwell time of the inventory corresponding with
the list entry is defined later by parameter "Interface Multiplexing Exposure Time
3".
Value range:
0x00 no antenna port
0x01 to 0x04 for the respective antenna port
Default: 0x03
Parameter 140
(0x8C)
RF Interface Multiplexing Antenna Port 4
Fourth list entry of the antenna port list!
The multiplexing antenna port list specifies the order of the antenna ports for a
multiple antenna inventory. The dwell time of the inventory corresponding with
the list entry is defined later by parameter "Interface Multiplexing Exposure Time
4".
Value range:
0x00 no antenna port
0x01 to 0x04 for the respective antenna port
Default: 0x04