Product Manual - RFID Reader UF70 Certum 143
Chapter 7
Operation
Parameter 133
(0x85)
Tag Comm Query Sel
Defines the transponders that participate in the query command. A detailed
description of the parameter is located in the EPC global specification for the
query command.
Value range: 0x00 to 0x03
Default: 0x00 (true)
Parameter 134
(0x86)
Host Comm Antenna Independend Operation
Antennas independent reading, i.e. for each transponder there is only one entry
in the observed list, even if it was read at different antennas.
Value range: 0x00 (false) or 0xFF (true)
Default: 0x00
Parameter 135
(0x87)
RF Interface Time to Power Off
The carrier follow-up time indicates how long the carrier remains on after a
transponder operation (subject to the restrictions of the selected communications
standard).
Value range: 0 to 65,535 s
Default: 0x0005 (5 s)
Parameter 136
(0x88)
RF Interface Modulation Type
Modulation type
Value range: 0 (DSB) and 1 (PR-ASK)
Default: 0x01 (PR-ASK)
Parameter 137
(0x89)
RF Interface Multiplexing Antenna Port 1
First list entry of the antenna port list!
The multiplexing antenna port list specifies the order of the antenna ports for a
multiple antenna inventory. The dwell time of the inventory corresponding with
the list entry is defined later by the parameter "Interface Multiplexing Exposure
Time 1".
Value range:
0x00 no antenna port
0x01 to 0x04 for the respective antenna port
Default: 0x01