Parameter 127
(0x7F)
Comm Standard Min Channel Wait Time
Parameters for the communications standard "specific".
Channel width in kHz
Value range: 0 to 65,535 kHz
Default: 0x0000
Parameter 128
(0x80)
Comm Standard First Channel
Parameters for the communications standard "specific".
Number of the first channel
Value range: 0 to 255
Default: 0x00
Parameter 129
(0x81)
Comm Standard Last Channel
Parameters for the communications standard "specific".
Number of the last channel
Value range: 0 to 255
Default: 0x00
Parameter 130
(0x82)
Tag Comm Intelligent Write
Only the changing data are written again during intelligent writing.
Value range: 0x00 (false) and 0xFF (true)
Default: 0xFF (true)
Parameter 131
(0x83)
Tag Comm Verify Write
Written data are verified again by the control reading.
Value range: 0x00 (false) and 0xFF (true)
Default: 0xFF (true)
Parameter 132
(0x84)
Tag Comm Query Target
Only transponders with a corresponding inventoried flag (A or B) participate in
the inventory round. A detailed description of the parameter is located in the EPC
global specification for the query command.
Value range: 0x00 (target A) and 0x01 (target B)
Default: 0x00