User's Manual

Table Of Contents
Product Manual - RFID Reader UF70 Certum 140
Chapter 7
Operation
Parameter 116
(0x74)
Antenna gain port 3
This value defines the antenna gain of the antenna connected to port 3.
Value range:
-128 to 127 (-32 dB to 31.75 dB; increment 0.25 dB)
Default: 0x14 (5 dB)
Parameter 117
(0x75)
Antenna gain port 4
This value defines the antenna gain of the antenna connected to port 4.
Value range:
-128 to 127 (-32 dB to 31.75 dB; increment 0.25 dB)
Default: 0x14 (5 dB)
Parameter 118
(0x76)
Extended Result Flag
This value defines the data of a detected transponder that are also displayed.
Value range: see information unit "Ex flag" and "Extensions" in
Message items
Default: 0x01 (antenna port only)
Parameter 119
(0x77)
Glimpsed Timeout Count
Number of unsuccessful inventories until a transponder that was previously
detected was removed from the transponder list.
Value range: 0x00 to 0xFF
Default: 0x03
Parameter 120
(0x78)
Observed Threshold Count
Number of successful transponders before it elevated into the "observed" status
(generating of "incoming" message).
Value range: 0x00 to 0xFF
Default: 0x05
Parameter 121
(0x79)
Observed Timeout Count
Number of unsuccessful inventories until an "observed" transponder looses the
"observed" status (generating an "outgoing" message).
Value range: 0x00 to 0xFF
Default: 0x05