Product Manual - RFID Reader UF70 Certum 135
Chapter 7
Operation
Parameter 41
(0x29)
Show UHF Going
When polling is activated by the EPC transponders (asynchronous reading), the
detection as well as the removal of EPC transponders can be displayed.
Value range:
0x00 to 0x03
Bit 0 (0x01): In addition to detecting also display the removal of an
EPC transponder
Bit 1 (0x02): During an inventory display the deviation of the RSSI value
to the amount of the value of the configuration parameter
(Par. 0xB2) in comparison to the RSSI value of the previous
inventory
Default: 0x00 (only show detection)
Parameter 93
(0x5D)
Wait Time Reader Response (read only)
This internal parameter can only be read.
Default: 0x9C (counter 0x9C00)
Parameter 94
(0x5E)
Wait Time Reader Acknowledge (read only)
This internal parameter can only be read.
Default: 0x14 (counter 0x1400)
Parameter 95
(0x5F)
Reader Control Time (read only)
This internal parameter can only be read.
Default: 0x0A (1 s)
Parameter 96
(0x60)
Stop Automatic Read (read only)
Internal parameter that can only be read. Setting the internal parameter causes
the automatic reading to be terminated when the sensor drops prematurely.
Default: 0x01 (active)
Parameter 97
(0x61)
Stop Sensor Message (read only)
Internal parameter that can only be read. Setting of the internal parameter
causes the cessation of unconfirmed repetitive sensor messages if the state of the
sensor changes.
Default: 0x01 (active)