User's Manual

Table Of Contents
Product Manual - RFID Reader UF70 Certum 118
Chapter 7
Operation
Q – Queries of the
output status
The current status of an output can be queried by using the Q command. The
status of the outputs of a single antenna port or the entire device can be queried.
For a single antenna port, the reader reports the status of the output. Use the
Head ID 0 to query the status of all outputs of the reader. The status of each
output is represented by 3 characters (status + flash rate).
Example: (Query after reset, no output was set)
>> Q01
<< q013
>> Q02
<< q023
>> Q03
<< q033
>> Q04
<< q043
>> Q00
<< q003333
Example: I/Os were set
>> O010
<< o01
>> O011
<< o01
>> O021
<< o02
>> O031
<< o03
>> O041
<< o04
>> Q00
<< q001111
>> Q01
<< q011
>> Q02
Host reader
CMD Reader ID Head ID
Q 1 byte 1 byte
Reader host
CMD Reader ID Head ID Output state
q 1 byte 1 or 4 Bytes 1 or 4 Bytes