9.5 System Errors
9.5.1 S9F1: UNRECOGNIZED DEVICE ID ( reader -> host )
The device-ID in the message block header did not correspond to the equipment
device ID’s.
S9F1
<B[10] MHEAD > .
9.5.2 S9F3: UNRECOGNIZED STREAM TYPE (reader -> host )
The reader does not recognize the stream type in the message block header.
S9F3
<B[10] MHEAD > .
9.5.3 S9F5: UNRECOGNIZED FUNCTION TYPE (reader -> host )
The reader does not recognize the function number in the message block header.
S9F5
<B[10] MHEAD > .
9.5.4 S9F7: ILLEGAL DATA (reader -> host )
The reader does not recognize the data in the message block header.
S9F5
<B[10] MHEAD > .
9.5.5 S9F9: TRANSACTION TIMER TIME-OUT ( reader -> host )
This message indicates that a transaction timer has timed out and that the
corresponding transaction has been aborted. Only the last sent message which has
to be confirmed by the host is stored and controlled.
S9F9
<B[10] SHEAD > .