User's Manual

RS232-Transponder Reader
(SECS1-Protocol), Release 0.3 Draft Page 56 of 91
2000-09-29
ID: ID000093
MIDAC Format: B[1]
Acknowledge Code
0 : material-ID acknowledged; the sensor 0 was the initiator
1 : not defined
2 : material-ID acknowledged - reaction on externally triggered action;
the message cannot be related to any sensor
>2 : material-ID not acknowledged
The initiator can be determined from the data item Portnumber PTN.
Where used: S3F14, S3F68
MIDRA Format: B[1]
Material ID acknowledge code
2: acknowledge, will send MID later in S3F13 or S3F67
Where used: S3F12
OBJSPEC Format: A[x]
Description: A text string that has an internal format and that is used to point to
a specific object instance. The string is formed out of a sequence
of formatted substrings, each specifying an object’s type and
identifier. The substring format has the following four fields.
Object type, colon character ”:” object identifier, greater-than symbol “>”
Where the colon character “:” is used to terminate an object type
and the greater than symbol “>” is used to terminate an identifier
field. The object type field may be omitted where it may be
otherwise determined. The final “>” is optional.