User's Manual

RS232-Transponder Reader
(SECS1-Protocol), Release 0.3 Draft Page 54 of 91
2000-09-29
ID: ID000093
Parameter 28: transmitter-level
The intensity of field strength to load a transponder.
The default value (1) should not change!
0 reduced field strength
1 maximum field strength
default: (1) maximum field strength
Parameter 29: transponder load duration
The used time to load a transponder.
The default value (50ms) should not change!
00 .. 255 ms
default: (50) 50ms
Parameter 30: not defined !
Parameter 31: not defined !
Parameter 32: not defined !
Parameter 33: automatic environment adjustment
The influence of interferences in the environment of the readers can be minimized
by an automatic adjustment during the operation. If the automatic adjustment is
deactivated, an adjustment to the environment will only be effected in case of a
reset.
0: deactivated automatic environment adjustment
1: activated automatic environment adjustment
default: (0) deactivated
Parameter 34: sensortype for sensor 0
Type of sensor signal to start the auto read if using one sensor:
0: auto read starts if sensor 0 is covered
1: auto read starts if sensor 0 is interrupted
default: (0) sensor 0 is covered
Where used: S2F13, S2F15
MDLN Format: A[6]
Equipment Model Number.
Where used: S1F2