User's Manual

RS232-Transponder Reader
(SECS1-Protocol), Release 0.3 Draft Page 53 of 91
2000-09-29
ID: ID000093
Parameter 21: not defined!
Parameter 22: sensor triggered action for sensor 0 and sensor 1
0 : read all transponders
1 : read the page 1 of a multipage-transponder
...
17 : read the page 17 of a multipage-transponder
240 : read a read/only-transponder
241 : read a read/write-transponder
default: : (0) read all transponders
Parameter 23: triggered read-frequency
Time between two attempts to read or write a transponder;
the read-frequency if there is a triggered read (no polling).
15 .. 100 % from 1s
default: (50%) 500ms
Parameter 24: r/w maxrepeat
Maximum number of repeat attempts to read or write a transponder
0 .. 255
default: 20
Parameter 25: not defined !
Parameter 26: sensor activity
The transponder reader offers the possibility to deactivate the connected sensor.
Parameter 26 realizes this with the following values:
0 No sensor defined
1 Only sensor 0 defined
default: 1
Parameter 27: watchport for sensor 0
Enables a message to the host, if a cassette is detected on I/O port or is removed
from I/O port.
A sensor is needed to use this message! :
0 report nothing
1 report cassette is removed
2 report cassette is detected
3 report cassette is detected and cassette is removed
default: (1) report cassette is removed