Parameter 1: Baudrate
Data transmission rate to the SECS-Host
3 : 300 Baud
6: 600 Baud
12: 1200 Baud
24: 2400 Baud
48: 4800 Baud
96: 9600 Baud
192: 19200 Baud
200: 38400 Baud
201: 57600 Baud
202: 115200 Baud
default: (200) 38400 Baud (look covering letter of the reader)
Parameter 2: Inter-Character-Timeout T1
1 .. 100 1/10s
default: (5) 0.5s
Parameter 3 : Block-Protocol-Timeout T2
2 .. 250 1/10s
default: (100) 10s
Parameter 4: Reply-Timeout T3
1 .. 120 1s
default: 45s
Parameter 5: Inter-Block Timeout T4
This parameter is without effect at the moment when no used message is larger
than a block.
1 .. 120 1s
default: 45s
Parameter 6: Retry-Limit RTY
Number how often a question or a message shall be repeated.
0 .. 31
default: 3
Parameter 7-19: not defined !
Parameter 20: sensordelay for sensor 0
Delay for auto read if using a sensor:
0 .. 255 1/10 s
default: (10) 1s