User's Manual
RS232-Transponder Reader
(SECS1-Protocol), Release 0.3 Draft Page 21 of 91
2000-09-29
ID: ID000093
3.6 Technical Data Antenna Cable
3.6.1 Cable of Rod Antenna and Frame Antenna
diameter : 5,5mm
bending radius: 15 x diameter, only once 6 x diameter
material: PVC
3.6.2 Cable of Mini Antenna and Micro Antenna
diameter : 4,1mm
bending radius: 20 x diameter, only once 5 x diameter
material: PVC
3.7 Technical Data Transponder-Reader
Parameter Value
Operation temperature 0 to +50°C
Stock temperature -25 to +70 °C
Permissible humidity @ 50C° 25 - 80 %
Transmitter frequency 134.2 kHz
Max. transmitting level in 3m distance
104 dBµV/m
Typ. period of charging impulse 50ms
Max. repeat of reading 4/s
Max. repeat of programming 1/s
Protection mode IP 40
Housing material ABS (UL94-V0)
Weight (with rod antenna and presence sensor) about 440g
Fuse type TR5 500mA (T)
Serial interface RS232 300 Bd – 115,2 kBd