The CID is defined as an ASCII value. Lowest value is <space> (0x20), up to
<DEL> (0x7F). The CID is displayed without of characters which are less than
0x31 hex = ASCII ‘1’ as leading digit.
e.g.:
CID: 0000000000120034 displayed as 120034 (leading ASCII ‘0’)
CID: 0x00..0x00 120034 displayed as 120034 (leading 0x00 hex)
CID: 5555555555120034 displayed as 5555555555120034 (leading ASCII ‘5’)
The sensor delay is the time between the moment the pod is placed on the
station and the sensor is switched. The sensor delay time is only valid for placing
the pod on the station, not for removing the pod.
Sensor delay is a two digit value for 01 to 99.
(01 = 100ms, 02 = 200ms, … , 99 = 9,9 seconds)
Blank byte is defined to fill not used pages of the tag. It is stored like product and
layer filler with identically range. The blank bytes will not checked by verification!
Follow the button description which is shown on the right side of the display.
4.3 Download
This option is needed to update the software of the equipment.
For this you need a software update tool which you can get from HERMOS. For
detailed information read the documentation of this tool.