User's Manual
Software Reticle Read – Write Station – Stand Alone
Technical Reports, Release 1.1
Page 5 of 15
Logistical layout of functionality:
1. RSP will be placed on Reticle Read / Write Station.
2. The RF tag will be read automatically and the result will be shown on the
display.
3. The operator writes the label data to the tag. Therefore he reads the
labels with the bar code reader. If the bar codes were read correctly the
operator verifies the data. If everything was OK the operator presses the
‘Write’ button to transmit the data to the RF tag. Not used bytes will be
filled with values which are stored as parameters in the software.
4. After a successful writing the pod could be removed from the unit.
5. It is possible to verify the tag data against the bar code labels. Therefore
the operator presses the ‘Verify’ button and reads the labels ones more.
After that the tag reader gets the information from the RF tag. The
software checks the data of both the tag and the bar code and reports
any error.
6. If the operator reads a wrong label it is possible to clear the data /
memory by pressing the ‘Reset’ button.