User's Manual

Table Of Contents
Product Manual - RFID Reader LF60C SoliD 97
Chapter 7
Operation
Parameter 0
(0x00)
Gateway ID
The gateway ID is a part of the device ID. The BROOKS reader works
simultaneously as a gateway and as a reader (CIDRW with integrated head).
It is the "lower message ID" in the message header.
00 .. 255
Default: Last two characters of hex serial number
The default gateway ID corresponds to parameter 8 (low byte TargetID).
Parameter 1
(0x01)
Baudrate
Data transmission rate to the SECS-Host
3: 300 Baud
6: 600 Baud
12: 1,200 Baud
24: 2,400 Baud
48: 4,800 Baud
96: 9,600 Baud
192: 19,200 Baud
200: 38,400 Baud
201: 57,600 Baud
202: 115,200 Baud
Default: (192) 19,200 Baud (see accompanying letter of the reader)
37 0x25 MID area
38 0x26 Test after software reset
40 0x28 Transponder load duration (write-mode)
41 0x29 Delay time between read cycles
42 0x2A CarrierIDOffset
43 0x2B CarrierIDLength
44 0x2C FixedMID
46 0x2D MIDFormat
98 0x62 Protocol change allowed
99 0x63 Customer code
No.
(dec.)
No.
(hex)
Parameter name