User's Manual

Table Of Contents
Product Manual - RFID Reader LF60C SoliD 87
Chapter 7
Operation
Multipage-transponder (page 1 to page 17):
Start the reading or writing on the following page of a multipage transponder:
...
"01" page 1 "81" Locked page 1
... ...
"11" page 17 "91" Locked page 17
Read/only transponder "F0" Read only the one page
Read/only transponder "F1" Read or write only the one page
Where used S18F5, S18F7
Acknowledge code for new reader constant
0 ... Parameter was set successfully
1 ... Parameter could not be set
Where used S2F16
DATALENGTH Format: U2
Description Total bytes to be sent.
The DATALENGTH corresponds to the quantity of bytes that are to be read or
written.
The valid range depends on the length of the MID area (parameter 37).
Where used S18F5, S18F7
DATASEG Format:A[2]
Description Used to identify the data requested.
The DATASEG corresponds to the page number (PAGEID) of the ISO 15693
transponder.
"00" First page of any type of transponder or first page of
DATA area in case of a multipage transponder.
EAC Format: B[1]