Product Manual - RFID Reader LF60C SoliD 86
Chapter 7
Operation
Description Status request value
OpStatus
Operation status Maintenance or Idle
"OP" ... Operating status
"MT" ... Maintenance status
LEDStatus
LED state
"Off" ... Switch LED off
"On" ... Switch LED on
"Flash" ... Switch LED to flash with 1Hz
LedNO
LED number, 1 byte
"1" Status LED
"2" Status LED
"3" External output
"4" Read OK LED
"5" Read Fail LED
Timeout
Timeout period
Units Seconds
Range "1" - "98"
"99" has a special meaning: it specifies "always". For example, a LED is turned on
with the TIMEOUT value of 99; it will stay on until the host turns it off or the
device is reset.
Where used S18F13
Description A vector or string of unformatted data.
Multipage transponder DATA area depends on the MID area,
can be page 1 - page 17
Read/write transponder DATA correspond to 8 byte MID
Read/only transponder DATA correspond to 8 byte MID
Where used S18F6, S18F7
CPVAL Format: A[]
DATA
Format:
A [max 200]