User's Manual
Table Of Contents
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Protocol change
- 7.3 Operation of the ASC-I1 protocol
- 7.3.1 Structure of the communication protocol
- 7.3.2 Package contents
- 7.3.3 Commands of protocol
- Commands host to reader
- Commands reader to host
- Message items
- X - Read data
- W - Write data
- R - Automatic read
- G - Request parameter value
- P - Set parameter
- N - Reset
- e - Error message
- H - Heartbeat
- V - Query software version
- L - Lock a page of the transponder
- I - Set tuning of the RF module
- J - Request tuning settings of RF module
- A - Sensor event
- 7.3.4 Parameters
- 7.3.5 Message examples
- 7.4 Operation of SECS/HSMS Protocol
- 7.4.1 Introduction
- 7.4.2 SECS-I implementation
- 7.4.3 HSMS option
- 7.4.4 HSMS implementation
- 7.4.5 SECS-II implementation
- 7.4.6 Parameters
- Parameter 0 (0x00)
- Parameter 1 (0x01)
- Parameter 2 (0x02)
- Parameter 3 (0x03)
- Parameter 4 (0x04)
- Parameter 5 (0x05)
- Parameter 6 (0x06)
- Parameter 7 (0x07)
- Parameter 8 (0x08)
- Parameter 9 (0x09)
- Parameter 11 (0x0B)
- Parameter 12 (0x0C)
- Parameter 20 (0x14)
- Parameter 22 (0x16)
- Parameter 23 (0x17)
- Parameter 24 (0x18)
- Parameter 25 (0x19)
- Parameter 26 (0x1A)
- Parameter 27 (0x1B)
- Parameter 29 (0x1D)
- Parameter 30 (0x1E)
- Parameter 31 (0x1F)
- Parameter 32 (0x20)
- Parameter 33 (0x21)
- Parameter 34 (0x22)
- Parameter 35 (0x23)
- Parameter 36 (0x24)
- Parameter 37 (0x25)
- Parameter 38 (0x26)
- Parameter 40 (0x28)
- Parameter 41 (0x29)
- Parameter 42 (0x2A)
- Parameter 43 (0x2B)
- Parameter 44 (0x2C)
- Parameter 45 (0x2D)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- 7.4.7 SEMI E99
- 7.4.8 Message details
- 7.4.9 HSMS message examples
- 7.4.10 SECS-I message examples
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- 11 Accessories
Product Manual - RFID Reader LF60C SoliD 83
Chapter 7
Operation
Alarm text
The length of the alarm text is 0 to 40 characters.
According to the reader version, status information about the sensor or sensors is
also transmitted during a reader error message.
The information should be interpreted as follows:
ALTX[0] Initiator of an error message
“0”: Sensor 0
“1”: Sensor 1 (not available)
“F”: Cannot be assigned
ALTX[1] Status of sensor 0
“0”: Sensor not occupied
“1”: Sensor is occupied
“E”: Sensor status is not available
“F”: Sensor not defined
ALTX[3] ‘:’ a colon separates the alarm text from the sensor statuses
Where used S5F1
Description: Identifier for an attribute for a specific type of object.
CIDRW attribute definitions:
"Configuration"… Number of heads
"AlarmStatus” Current CIDRW sub-status of ALARM STATUS
"OperationalStatus" Current CIDRW sub-status of OPERATING
"SoftwareRevisionLevel" Revision (version) of software - 8-byte maximum
"CarrierIDOffset" Offset of CID in CID field (MID area)
"CarrierIDLength" Length of CID in CID field (MID area)
"SERIALNUM” String of Serial number
"HARDWARE" String of hardware release
"SELF_TEST_RESULT" Delivers the result from the last triggered self test
"MANUFACTURER" String of manufacturer
"ECID_00" parameter 0 - Gateway ID (ECID=0)
"ECID_01" parameter 1 - Baudrate (ECID=1)
"ECID_02" parameter 2 - Inter-character-timeout T1
"ECID_03" parameter 3 - Block-protocol-timeout T2
"ECID_04" parameter 4 - Reply-timeout T3
"ECID_05" parameter 5 - Inter-block-timeout T4
ALTX Format: A[max40]
ALTRID Format: A[max25]