Alarm text
The length of the alarm text is 0 to 40 characters.
According to the reader version, status information about the sensor or sensors is
also transmitted during a reader error message.
The information should be interpreted as follows:
ALTX[0] Initiator of an error message
“0”: Sensor 0
“1”: Sensor 1 (not available)
“F”: Cannot be assigned
ALTX[1] Status of sensor 0
“0”: Sensor not occupied
“1”: Sensor is occupied
“E”: Sensor status is not available
“F”: Sensor not defined
ALTX[3] ‘:’ a colon separates the alarm text from the sensor statuses
Where used S5F1
Description: Identifier for an attribute for a specific type of object.
CIDRW attribute definitions:
"Configuration"… Number of heads
"AlarmStatus” Current CIDRW sub-status of ALARM STATUS
"OperationalStatus" Current CIDRW sub-status of OPERATING
"SoftwareRevisionLevel" Revision (version) of software - 8-byte maximum
"CarrierIDOffset" Offset of CID in CID field (MID area)
"CarrierIDLength" Length of CID in CID field (MID area)
"SERIALNUM” String of Serial number
"HARDWARE" String of hardware release
"SELF_TEST_RESULT" Delivers the result from the last triggered self test
"MANUFACTURER" String of manufacturer
"ECID_00" parameter 0 - Gateway ID (ECID=0)
"ECID_01" parameter 1 - Baudrate (ECID=1)
"ECID_02" parameter 2 - Inter-character-timeout T1
"ECID_03" parameter 3 - Block-protocol-timeout T2
"ECID_04" parameter 4 - Reply-timeout T3
"ECID_05" parameter 5 - Inter-block-timeout T4
ALTX Format: A[max40]
ALTRID Format: A[max25]