User's Manual
Table Of Contents
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Protocol change
- 7.3 Operation of the ASC-I1 protocol
- 7.3.1 Structure of the communication protocol
- 7.3.2 Package contents
- 7.3.3 Commands of protocol
- Commands host to reader
- Commands reader to host
- Message items
- X - Read data
- W - Write data
- R - Automatic read
- G - Request parameter value
- P - Set parameter
- N - Reset
- e - Error message
- H - Heartbeat
- V - Query software version
- L - Lock a page of the transponder
- I - Set tuning of the RF module
- J - Request tuning settings of RF module
- A - Sensor event
- 7.3.4 Parameters
- 7.3.5 Message examples
- 7.4 Operation of SECS/HSMS Protocol
- 7.4.1 Introduction
- 7.4.2 SECS-I implementation
- 7.4.3 HSMS option
- 7.4.4 HSMS implementation
- 7.4.5 SECS-II implementation
- 7.4.6 Parameters
- Parameter 0 (0x00)
- Parameter 1 (0x01)
- Parameter 2 (0x02)
- Parameter 3 (0x03)
- Parameter 4 (0x04)
- Parameter 5 (0x05)
- Parameter 6 (0x06)
- Parameter 7 (0x07)
- Parameter 8 (0x08)
- Parameter 9 (0x09)
- Parameter 11 (0x0B)
- Parameter 12 (0x0C)
- Parameter 20 (0x14)
- Parameter 22 (0x16)
- Parameter 23 (0x17)
- Parameter 24 (0x18)
- Parameter 25 (0x19)
- Parameter 26 (0x1A)
- Parameter 27 (0x1B)
- Parameter 29 (0x1D)
- Parameter 30 (0x1E)
- Parameter 31 (0x1F)
- Parameter 32 (0x20)
- Parameter 33 (0x21)
- Parameter 34 (0x22)
- Parameter 35 (0x23)
- Parameter 36 (0x24)
- Parameter 37 (0x25)
- Parameter 38 (0x26)
- Parameter 40 (0x28)
- Parameter 41 (0x29)
- Parameter 42 (0x2A)
- Parameter 43 (0x2B)
- Parameter 44 (0x2C)
- Parameter 45 (0x2D)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- 7.4.7 SEMI E99
- 7.4.8 Message details
- 7.4.9 HSMS message examples
- 7.4.10 SECS-I message examples
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- 11 Accessories
Product Manual - RFID Reader LF60C SoliD 78
Chapter 7
Operation
Data items The formats represent arrays of types: <type>[number of elements], whereby
<type> is one of the following:
Oct-
code
Hex-
code
Format Meaning Example
00 01 List List element with the
number of the
"Length" data
elements
<L2>
<A "Hello">
<B 0x00>
11 25 Boolean 1-byte Boolean
false = 00
true = 01
<Boolean1 0x00>
10 21 Binary Byte sequence
of the length "Length"
<B1 0x01>
20 41 ASCII Printable ASCII
characters
<A "Hello">
31 65 I1 1-byte signed integer <I1 123>
32 69 I2 2-byte signed integer <I2 -12345>
34 71 I4 4-byte signed integer <I4 2147483647>
30 61 I8 8-byte signed integer <I8
931372980293834>
51 A5 U1 1-byte unsigned
integer
<U1 0>
52 A9 U2 2-byte unsigned
integer
<U2 #empty>
54 B1 U4 4-byte unsigned
integer
<U4 429489725>
50 A1 U8 8-byte unsigned
integer
<U8
763468676756767>
40 91 F8 8-byte floating point <F8 1.223 e204>
44 81 F4 4-byte floating point <F4 -1.23 >