Chapter 7
Operation
Parameter 2
(0x02)
Read page
Page for readmode "00".
00 - First page of any type of transponder
01 .. 17 - Page of multipage transponder
Default: 00 (first page of any type of transponder)
Parameter 3
(0x03)
r/w repeat time
Time between two read or write attempts.
01 .. 99 (0.1 s)
Default: 05 (0.5 s)
Parameter 4
(0x04)
r/w max repeat
Maximum number of read/write attempts.
01 .. 99
Default: 05
Parameter 5
(0x05)
RS232 repeat time
In case no confirmation message from the host was received, the device waits
this time before sending a repeat message. The number of repeats is defined in
parameter 6 (RS232 maxrepeat).
01.. 99 (0.1 s)
Default: 45 (4.5 s)
Parameter 6
(0x06)
RS232 max repeat
If the host does not send the expected confirmation message, the device repeats
the message according the value of this parameter. After that, an error message
is sent.
00 - never ending
01 .. 99 - number of attempts
Default: 3
Parameter 7
(0x07)
Watch port
Enables/disables the event message to the host that the floating contact
(external input) was opened.
00 - not activated (no event message)
01 - activated
Default: 1