User's Manual
Table Of Contents
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Protocol change
- 7.3 Operation of the ASC-I1 protocol
- 7.3.1 Structure of the communication protocol
- 7.3.2 Package contents
- 7.3.3 Commands of protocol
- Commands host to reader
- Commands reader to host
- Message items
- X - Read data
- W - Write data
- R - Automatic read
- G - Request parameter value
- P - Set parameter
- N - Reset
- e - Error message
- H - Heartbeat
- V - Query software version
- L - Lock a page of the transponder
- I - Set tuning of the RF module
- J - Request tuning settings of RF module
- A - Sensor event
- 7.3.4 Parameters
- 7.3.5 Message examples
- 7.4 Operation of SECS/HSMS Protocol
- 7.4.1 Introduction
- 7.4.2 SECS-I implementation
- 7.4.3 HSMS option
- 7.4.4 HSMS implementation
- 7.4.5 SECS-II implementation
- 7.4.6 Parameters
- Parameter 0 (0x00)
- Parameter 1 (0x01)
- Parameter 2 (0x02)
- Parameter 3 (0x03)
- Parameter 4 (0x04)
- Parameter 5 (0x05)
- Parameter 6 (0x06)
- Parameter 7 (0x07)
- Parameter 8 (0x08)
- Parameter 9 (0x09)
- Parameter 11 (0x0B)
- Parameter 12 (0x0C)
- Parameter 20 (0x14)
- Parameter 22 (0x16)
- Parameter 23 (0x17)
- Parameter 24 (0x18)
- Parameter 25 (0x19)
- Parameter 26 (0x1A)
- Parameter 27 (0x1B)
- Parameter 29 (0x1D)
- Parameter 30 (0x1E)
- Parameter 31 (0x1F)
- Parameter 32 (0x20)
- Parameter 33 (0x21)
- Parameter 34 (0x22)
- Parameter 35 (0x23)
- Parameter 36 (0x24)
- Parameter 37 (0x25)
- Parameter 38 (0x26)
- Parameter 40 (0x28)
- Parameter 41 (0x29)
- Parameter 42 (0x2A)
- Parameter 43 (0x2B)
- Parameter 44 (0x2C)
- Parameter 45 (0x2D)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- 7.4.7 SEMI E99
- 7.4.8 Message details
- 7.4.9 HSMS message examples
- 7.4.10 SECS-I message examples
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- 11 Accessories
Product Manual - RFID Reader LF60C SoliD 38
Chapter 6
Installation
LF60CM
5-pin connecting plug
6.12 DIP switches
The activation of a DIP switch depends on the value of parameter 36.
Switch # "Test mode" function
1 Deactivation of automatic protocol recognition from version
SG2S12
"OFF" - automatic protocol recognition active
"ON" - automatic protocol recognition deactivated
The protocol setting depends on the DIP2 switch setting.
2 Protocol selection (only if DIP1 is set to "ON") from version
SG2S1
"OFF" - ASCII protocol
"ON" - SECS/HSMS protocol
3 - 5 No function
6 Switches between reading and writing action in test mode.
"OFF" only reading a tag
"ON" reading and writing a tag
7 Switches the reader into test mode.
In test mode, the reader reads or writes (depends on the
setting of switch 6) permanently to the tag, and shows the
result via LED 'Read/Write ok' and 'Read/Write fail'.
"ON" test mode activation
8 Launch automatic antenna tuning on switching from "OFF" to
"ON".