Product Manual - RFID Reader LF60C SoliD 154
Chapter 8
Service and Troubleshooting
8.7 Reset
8.8 Power cut
After a power cut, the reader performs a reset with self-test. The self-test can
take up to five seconds. In the first step of these self-tests, all LEDs (status, read
fail, read ok) light up. In the second step, the reader displays the selected
protocol type. The read fail LED signalizes the SECS-II protocol. The read ok LED
signalizes the ASCII protocol.
If the test was successful, all LEDs, except for the power LED, go out.
8.9 Software releases
In the case of a malfunction, a hardware reset can be performed by
switching the power supply off and on!
After the reset, the reader performs a self-test. The self test can take up to
five seconds. As the first step in these self-tests, all LEDs (Status, Read OK
and Read Fail) light up. At the second step, the reader displays the selected
protocol type. The read fail LED signalizes the SECS-II protocol. The read
ok LED signalizes the ASCII protocol. If the test was successful, all LEDs
except the power LED go out!
Release
Date
Version Description
May 2011
SG2S10/SG2IV1.0
First version
Januar 2012
SG2S11/SG2IV1.1
Hardware version 25 characters long,
serial UDP protocol, parity and baud rate
can also be set in ASCII
Mai 2012
SG2S12/SG2IV1.2
Auto. protocol recognition can be
deactivated with DIP1, manual protocol
setting with DIP2