User's Manual
Table Of Contents
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Protocol change
- 7.3 Operation of the ASC-I1 protocol
- 7.3.1 Structure of the communication protocol
- 7.3.2 Package contents
- 7.3.3 Commands of protocol
- Commands host to reader
- Commands reader to host
- Message items
- X - Read data
- W - Write data
- R - Automatic read
- G - Request parameter value
- P - Set parameter
- N - Reset
- e - Error message
- H - Heartbeat
- V - Query software version
- L - Lock a page of the transponder
- I - Set tuning of the RF module
- J - Request tuning settings of RF module
- A - Sensor event
- 7.3.4 Parameters
- 7.3.5 Message examples
- 7.4 Operation of SECS/HSMS Protocol
- 7.4.1 Introduction
- 7.4.2 SECS-I implementation
- 7.4.3 HSMS option
- 7.4.4 HSMS implementation
- 7.4.5 SECS-II implementation
- 7.4.6 Parameters
- Parameter 0 (0x00)
- Parameter 1 (0x01)
- Parameter 2 (0x02)
- Parameter 3 (0x03)
- Parameter 4 (0x04)
- Parameter 5 (0x05)
- Parameter 6 (0x06)
- Parameter 7 (0x07)
- Parameter 8 (0x08)
- Parameter 9 (0x09)
- Parameter 11 (0x0B)
- Parameter 12 (0x0C)
- Parameter 20 (0x14)
- Parameter 22 (0x16)
- Parameter 23 (0x17)
- Parameter 24 (0x18)
- Parameter 25 (0x19)
- Parameter 26 (0x1A)
- Parameter 27 (0x1B)
- Parameter 29 (0x1D)
- Parameter 30 (0x1E)
- Parameter 31 (0x1F)
- Parameter 32 (0x20)
- Parameter 33 (0x21)
- Parameter 34 (0x22)
- Parameter 35 (0x23)
- Parameter 36 (0x24)
- Parameter 37 (0x25)
- Parameter 38 (0x26)
- Parameter 40 (0x28)
- Parameter 41 (0x29)
- Parameter 42 (0x2A)
- Parameter 43 (0x2B)
- Parameter 44 (0x2C)
- Parameter 45 (0x2D)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- 7.4.7 SEMI E99
- 7.4.8 Message details
- 7.4.9 HSMS message examples
- 7.4.10 SECS-I message examples
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- 11 Accessories
Product Manual - RFID Reader LF60C SoliD 151
Chapter 8
Service and Troubleshooting
* because the device is still busy or because a message has not been confirmed
by the previous read up to now
8.4.2 SSACK
C (12) bad type incorrect transponder
type
incorrect transponder
type is used (read only
or read/write instead of
Multipage)
check transponder type and replace
it
ID Name Description Possible cause Correcting action
SSACK Name Description Possible cause Correcting action
NO
Normal
mode
indicates the success of
the operation requested
- no
EE
Execute
error
transponder data and
read ID sequence can-
not be read
transponder has no or
too less valid ASCII
characters on MID area
program transponder with valid
ASCII characters on MID area
parameters for MID
area are not matching
transponder data
set reader parameters for MID area
corresponding to transponder data
area for the MID
reader is still busy with
a former read or write
request
wait until the former request is
done
incorrect reader mode
for operation
switch to correct mode (MANT for
writing MID)
CE
Commu-
nication
error
syntax error of message
ore message format or
incorrect value
data sent with a com-
mand are wrong
check syntax and data of command
list format, amount of
lists or data type is
wrong
check syntax of SECS message
sent parameter is not
implemented or not
within the range
check syntax and parameter value
HE
Hard-
ware
error
error in the head of the
ID reader/writer, head
of the ID reader/writer
is deactivated