User's Manual

Table Of Contents
Product Manual - RFID Reader LF60C SoliD 143
Chapter 7
Operation
Host requests a perform diagnostic with S18F13
the reader has no valid adjustment!
Host to Reader: S18F13
15:52:29 Outgoing: ENQ ( 05 )
15:52:29 Incoming: EOT ( 04 )
15:52:29 Outgoing: Length Byte ( 26 )
15:52:29 Outgoing: Header ( 01 34 92 0D 80 01 00 00 00 4A )
15:52:29 Outgoing: Data ( 01 03
41 02 30 31
41 12 50 65 72 66 6F 72 6D 44 69 61 67 6E 6F 73 74 69 63 73
"PerformDiagnostics"
01 00 )
15:52:29 Outgoing: Checksum ( 09 EE )
15:52:29 Incoming: ACK ( 06 )
Reader to Host: S18F14
15:52:29 Incoming: ENQ ( 05 )
15:52:29 Outgoing: EOT ( 04 )
15:52:29 Incoming: Length Byte ( 2B )
15:52:29 Incoming: Header ( 81 34 12 0E 80 01 00 00 00 4A )
15:52:29 Incoming: Data ( 01 03 41 02 30 )
15:52:29 Incoming: Data ( 31 41 02 4E 4F 01 01 01 )
15:52:29 Incoming: Data ( 04 41 02 4E 45 41 01 31 )
15:52:29 Incoming: Data ( 41 04 49 44 4C 45 41 04 )
15:52:29 Incoming: Data ( 49 44 4C 45 )
15:52:29 Incoming: Checksum ( 07 3E )
15:52:29 Outgoing: ACK ( 06 )
Host to Reader: S18F1
15:52:39 Outgoing: ENQ ( 05 )
15:52:39 Incoming: EOT ( 04 )
15:52:39 Outgoing: Length Byte ( 24 )
15:52:39 Outgoing: Header ( 01 34 92 01 80 01 00 00 00 4B )
15:52:39 Outgoing: Data ( 01 02
41 02 30 31
01 01
41 10 53 45 4C 46 5F 54 45 53 54 5F 52 45 53 55 4C 54 )
"SELF_TEST_RESULT"
15:52:39 Outgoing: Checksum ( 07 95 )
15:52:39 Incoming: ACK ( 06 )