Host changes the reader status from IDLE to MANT with S18F13
Host to Reader: S18F13
17:12:29 Outgoing: ENQ ( 05 )
17:12:29 Incoming: EOT ( 04 )
17:12:29 Outgoing: Length byte ( 25 )
17:12:29 Outgoing: Header ( 01 FF 92 0D 80 01 00 00 00 67 )
17:12:29 Outgoing: Data
01 03
41 04 31 32 33 34 ' TARGETID "1234"
41 0B 43 68 61 6E 67 65 53 74 61 74 65
SSCMD "ChangeStatus"
01 01
41 02 4D 54 CPVAL1 "MT"
17:12:29 Outgoing: Checksum ( 13 02 )
17:12:29 Incoming: ACK ( 06 )
Reader to Host: S18F14
17:12:29 Incoming: ENQ ( 05 )
17:12:29 Outgoing: EOT ( 04 )
17:12:29 Incoming: Length byte ( 2D )
17:12:29 Incoming: Header ( 81 FF 12 0E 80 01 00 00 00 67 )
17:12:29 Incoming: Data
01 03
41 04 31 32 33 34 TARGETID "1234"
41 02 4E 4F SSACK "NO"
01 01
01 04 STATUS <L4>
41 02 4E 45 PMInformation "NE"
41 01 30 Alarmstatus "0"
41 04 4D 41 4E 54 OperatingStatus "MANT"
41 04 4E 4F 4F 50 HeadStatus "NOOP"
17:12:29 Incoming: Checksum ( 08 C0 )
17:12:29 Outgoing: ACK ( 06 )
ChangeStatus is an optional service that requests the CIDRW to change its
operating sub status to MAINTENANCE ("MT") or to OPERATING ("OP").
In MAINTENANCE status, the reader could not read (S18F5) or write (S18F7) any
DATA in the defined DATASEG.