User's Manual

Table Of Contents
Product Manual - RFID Reader LF60C SoliD 135
Chapter 7
Operation
Host writes new reader attributes with S18F3
Host to Reader: S18F3
15:18:14 Outgoing: ENQ ( 05 )
15:18:14 Incoming: EOT ( 04 )
15:18:14 Outgoing: Length Byte ( 8E )
15:18:14 Outgoing: Header ( 01 34 92 03 80 01 00 00 00 44 )
15:18:14 Outgoing: Data ( 01 02 41 02 30 31
01 06
01 02
41 0D 43 6F 6E 66 69 67 75 72 61 74 69 6F 6E
41 02 30 31
01 02
41 11 4F 70 65 72 61 74 69 6F 6E 61 6C 53 74 61 74 75 73 41 04 49 44 4C 45
01 02
41 0B 41 6C 61 72 6D 53 74 61 74 75 73
41 01 31
01 02
41 0F 43 61 72 72 69 65 72 49 44 4F 66 66 73 65 74
41 01 30
01 02
41 06 48 65 61 64 49 44 41 01 31 01 02
41 0F 43 61 72 72 69 65 72 49 44 4C 65 6E 67 74 68
41 02 31 30 )
15:18:14 Outgoing: Checksum ( 26 62 )
15:18:14 Incoming: ACK ( 06 )
Reader to Host: S18F4
15:18:14 Incoming: ENQ ( 05 )
15:18:14 Outgoing: EOT ( 04 )
15:18:14 Incoming: Length Byte ( 2B )
15:18:14 Incoming: Header ( 81 34 12 04 80 01 00 00 00 44 )
15:18:14 Incoming: Data ( 01 03 41 02 30 31)
15:18:14 Incoming: Data ( 41 02 4E 4F)
15:18:14 Incoming: Data (01 01)
15:18:14 Incoming: Data (01 04)
15:18:14 Incoming: Data (41 02 4E 45)
15:18:14 Incoming: Data (41 01 31)
15:18:14 Incoming: Data (41 04 49 44 4C 45)
15:18:14 Incoming: Data (41 04 49 44 4C 45)
15:18:14 Incoming: Checksum ( 07 2E )
15:18:14 Outgoing: ACK ( 06 )
The host writes all fundamental CIDRW attributes defined in ATTRID.
The reader answers with the actual attribute values.