User's Manual
Table Of Contents
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Protocol change
- 7.3 Operation of the ASC-I1 protocol
- 7.3.1 Structure of the communication protocol
- 7.3.2 Package contents
- 7.3.3 Commands of protocol
- Commands host to reader
- Commands reader to host
- Message items
- X - Read data
- W - Write data
- R - Automatic read
- G - Request parameter value
- P - Set parameter
- N - Reset
- e - Error message
- H - Heartbeat
- V - Query software version
- L - Lock a page of the transponder
- I - Set tuning of the RF module
- J - Request tuning settings of RF module
- A - Sensor event
- 7.3.4 Parameters
- 7.3.5 Message examples
- 7.4 Operation of SECS/HSMS Protocol
- 7.4.1 Introduction
- 7.4.2 SECS-I implementation
- 7.4.3 HSMS option
- 7.4.4 HSMS implementation
- 7.4.5 SECS-II implementation
- 7.4.6 Parameters
- Parameter 0 (0x00)
- Parameter 1 (0x01)
- Parameter 2 (0x02)
- Parameter 3 (0x03)
- Parameter 4 (0x04)
- Parameter 5 (0x05)
- Parameter 6 (0x06)
- Parameter 7 (0x07)
- Parameter 8 (0x08)
- Parameter 9 (0x09)
- Parameter 11 (0x0B)
- Parameter 12 (0x0C)
- Parameter 20 (0x14)
- Parameter 22 (0x16)
- Parameter 23 (0x17)
- Parameter 24 (0x18)
- Parameter 25 (0x19)
- Parameter 26 (0x1A)
- Parameter 27 (0x1B)
- Parameter 29 (0x1D)
- Parameter 30 (0x1E)
- Parameter 31 (0x1F)
- Parameter 32 (0x20)
- Parameter 33 (0x21)
- Parameter 34 (0x22)
- Parameter 35 (0x23)
- Parameter 36 (0x24)
- Parameter 37 (0x25)
- Parameter 38 (0x26)
- Parameter 40 (0x28)
- Parameter 41 (0x29)
- Parameter 42 (0x2A)
- Parameter 43 (0x2B)
- Parameter 44 (0x2C)
- Parameter 45 (0x2D)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- 7.4.7 SEMI E99
- 7.4.8 Message details
- 7.4.9 HSMS message examples
- 7.4.10 SECS-I message examples
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- 11 Accessories
Product Manual - RFID Reader LF60C SoliD 132
Chapter 7
Operation
The reader detects wrong data and sends the S9F7 message
Host to Reader: S2F13
16:49:00 Outgoing: ENQ ( 05 )
16:49:00 Incoming: EOT ( 04 )
16:49:00 Outgoing: Length byte ( 0F )
16:49:00 Outgoing: Header ( 01 FF 82 0D 80 01 00 00 00 36 )
16:49:00 Outgoing: Data ( 01 01 A5 01 0F )
16:49:00 Outgoing: Checksum ( 79 02 )
16:49:00 Incoming: ACK ( 06 )
Reader to Host: S2F14
16:49:00 Incoming: ENQ ( 05 )
16:49:00 Outgoing: EOT ( 04 )
16:49:00 Incoming: Length byte ( 0E )
16:49:00 Incoming: Header ( 81 FF 02 0E 80 01 00 00 00 36 )
16:49:00 Incoming: Data ( 01 01 A5 00 )
16:49:00 Incoming: Checksum ( 02 EE )
16:49:00 Outgoing: ACK ( 06 )
Reader to Host: S9F7:
16:49:00 Incoming: ENQ ( 05 )
16:49:00 Outgoing: EOT ( 04 )
16:49:00 Incoming: Length byte ( 16 )
16:49:00 Incoming: Header ( 81 FF 09 07 80 01 00 07 00 1F )
16:49:00 Incoming: Data ( 21 0A 01 FF 82 )
16:49:00 Incoming: Data ( 0D 80 01 00 00 00 36 )
16:49:00 Incoming: Checksum ( 04 A8 )
16:49:00 Outgoing: ACK ( 06 )
The reader replies to the S2F13 equipment constant request message without
data, because the parameter was invalid. Additionally, the reader sends the S9F7
illegal data message.
The secondary message fails and the reader sends the S9F9
message
Reader to Host: S1F1
20:07:16 Incoming: ENQ ( 05 )
20:07:16 Outgoing: EOT ( 04 )
20:07:16 Incoming: Length byte ( 0A )
20:07:16 Incoming: Header ( 81 FF 81 01 80 01 00 00 00 01 )
20:07:16 Incoming: Checksum ( 02 84 )
20:07:16 Outgoing: ACK ( 06 )