User's Manual

Table Of Contents
Product Manual - RFID Reader LF60C SoliD 127
Chapter 7
Operation
New reader constant sent with S2F15
Host to Reader: S2F15
10:39:32 Outgoing: ENQ ( 05 )
10:39:32 Incoming: EOT ( 04 )
10:39:32 Outgoing: Length byte ( 14 )
10:39:32 Outgoing: Header( 01 FF 82 0F 80 01 00 00 00 07 )
10:39:32 Outgoing: Data
01 01
01 02
A5 01 14 Parameter 20
A5 01 05 Value 5
10:39:32 Outgoing: Checksum ( 83 02 )
10:39:32 Incoming: ACK ( 06 )
Reader to Host: S2F16
10:39:32 Incoming: ENQ ( 05 )
10:39:32 Outgoing: EOT ( 04 )
10:39:32 Incoming: Length byte ( 0D )
10:39:32 Incoming: Header( 81 FF 02 10 80 01 00 00 00 07 )
10:39:32 Incoming: Data ( 21 01 00 ) ECV 0
10:39:32 Incoming: Checksum ( 02 3C )
10:39:32 Outgoing: ACK ( 06 )
The host sets the reader parameter "20" (sensor delay) to the value "5".
The reader acknowledges the new constant with ECV = 0.
Host requests a software reset with S2F19
Host to Reader: S2F19
14:18:46 Outgoing: ENQ ( 05 )
14:18:46 Incoming: EOT ( 04 )
14:18:46 Outgoing: Length Byte ( 0D )
14:18:46 Outgoing: Header ( 01 34 82 13 80 01 00 00 00 2E )
14:18:46 Outgoing: Data ( 21 01 02 ) Software reset
14:18:46 Outgoing: Checksum ( 01 9D )
14:18:46 Incoming: ACK ( 06 )
Reader to Host: S2F20
14:18:46 Incoming: ENQ ( 05 )
14:18:46 Outgoing: EOT ( 04 )
14:18:46 Incoming: Length Byte ( 0D )
14:18:46 Incoming: Header ( 81 34 02 14 80 01 00 00 00 2E )
14:18:46 Incoming: Data ( 21 01 00 )
14:18:46 Incoming: Checksum ( 01 9C )
14:18:46 Outgoing: ACK ( 06 )