User's Manual

Table Of Contents
Product Manual - RFID Reader LF60C SoliD 126
Chapter 7
Operation
Message S1F17 puts the reader online
Host to Reader: S1F17
10:33:24 Outgoing: ENQ ( 05 )
10:33:24 Incoming: EOT ( 04 )
10:33:24 Outgoing: Length byte ( 0A )
10:33:24 Outgoing: Header ( 01 FF 81 11 80 01 00 00 00 04 )
10:33:24 Outgoing: Checksum ( 17 02 )
10:33:24 Incoming: ACK ( 06 )
Reader to Host: S1F18
10:33:24 Incoming: ENQ ( 05 )
10:33:24 Outgoing: EOT ( 04 )
10:33:24 Incoming: Length byte ( 0D )
10:33:24 Incoming: Header ( 81 FF 01 12 80 01 00 00 00 04 )
10:33:24 Incoming: Data ( 21 01 00 )
10:33:24 Incoming: Checksum ( 02 3A )
10:33:24 Outgoing: ACK ( 06 )
Request reader constant with message S2F13
Host to Reader (Gateway): S2F13
10:34:01 Outgoing: ENQ ( 05 )
10:34:01 Incoming: EOT ( 04 )
10:34:01 Outgoing: Length byte ( 0F )
10:34:01 Outgoing: Header ( 01 FF 82 0D 80 01 00 00 00 05 )
10:34:01 Outgoing: Data ( 01 01 A5 01 01 ) Parameter 1
10:34:01 Outgoing: Checksum ( 3A 02 )
10:34:01 Incoming: ACK ( 06 )
Reader to Host: S2F14
10:34:01 Incoming: ENQ ( 05 )
10:34:01 Outgoing: EOT ( 04 )
10:34:01 Incoming: Length byte ( 0F )
10:34:01 Incoming: Header ( 81 FF 02 0E 80 01 00 00 00 05 )
10:34:01 Incoming: Data ( 01 01 A5 01 C0 ) Value 192
10:34:01 Incoming: Checksum ( 03 7E )
10:34:01 Outgoing: ACK ( 06 )
The host requests the reader parameter "1" (transmission rate).
The reader sends the value "C0" (192) that confirms the 19,200 baud.