User's Manual
Table Of Contents
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Protocol change
- 7.3 Operation of the ASC-I1 protocol
- 7.3.1 Structure of the communication protocol
- 7.3.2 Package contents
- 7.3.3 Commands of protocol
- Commands host to reader
- Commands reader to host
- Message items
- X - Read data
- W - Write data
- R - Automatic read
- G - Request parameter value
- P - Set parameter
- N - Reset
- e - Error message
- H - Heartbeat
- V - Query software version
- L - Lock a page of the transponder
- I - Set tuning of the RF module
- J - Request tuning settings of RF module
- A - Sensor event
- 7.3.4 Parameters
- 7.3.5 Message examples
- 7.4 Operation of SECS/HSMS Protocol
- 7.4.1 Introduction
- 7.4.2 SECS-I implementation
- 7.4.3 HSMS option
- 7.4.4 HSMS implementation
- 7.4.5 SECS-II implementation
- 7.4.6 Parameters
- Parameter 0 (0x00)
- Parameter 1 (0x01)
- Parameter 2 (0x02)
- Parameter 3 (0x03)
- Parameter 4 (0x04)
- Parameter 5 (0x05)
- Parameter 6 (0x06)
- Parameter 7 (0x07)
- Parameter 8 (0x08)
- Parameter 9 (0x09)
- Parameter 11 (0x0B)
- Parameter 12 (0x0C)
- Parameter 20 (0x14)
- Parameter 22 (0x16)
- Parameter 23 (0x17)
- Parameter 24 (0x18)
- Parameter 25 (0x19)
- Parameter 26 (0x1A)
- Parameter 27 (0x1B)
- Parameter 29 (0x1D)
- Parameter 30 (0x1E)
- Parameter 31 (0x1F)
- Parameter 32 (0x20)
- Parameter 33 (0x21)
- Parameter 34 (0x22)
- Parameter 35 (0x23)
- Parameter 36 (0x24)
- Parameter 37 (0x25)
- Parameter 38 (0x26)
- Parameter 40 (0x28)
- Parameter 41 (0x29)
- Parameter 42 (0x2A)
- Parameter 43 (0x2B)
- Parameter 44 (0x2C)
- Parameter 45 (0x2D)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- 7.4.7 SEMI E99
- 7.4.8 Message details
- 7.4.9 HSMS message examples
- 7.4.10 SECS-I message examples
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- 11 Accessories
Product Manual - RFID Reader LF60C SoliD 113
Chapter 7
Operation
S2F16: NEW EQUIPMENT CONSTANT ACKNOWLEDGE (reader ->
host)
The reader acknowledges the setting of the reader constant.
S2F16
<B[1] EAC>.
S2F19: RESET SEND (host -> reader, reply)
The host requests the reader to reset the hardware and software.
If a heartbeat time is set (parameter 9), the reader sends an S1F1 message when
the reset is finished.
The power-up reset requires a few seconds.
S2F19 W
<B[1] RIC>.
S2F20: RESET ACKNOWLEDGE (reader -> host)
The reader acknowledges the reset.
This message will only appears if a software reset (RIC=2) is triggered.
S2F20
<B[1] RAC>.
Material status S3F0: ABORT TRANSACTION (reader <-> host)
Used instead of an expected reply to abort a transaction. Function 0 is defined in
every stream and has the same meaning in every stream.
S3F0 W. * Header Only
S3F5: CASSETTE FOUND SEND (reader -> host, reply)
The reader sends the information that a cassette was detected by the presence
sensor.
This message is sent only if a sensor is connected and activated (see parameters
27 'watchport' and 26 'sensor activity').
S3F5 W.
<L[2]
<B[1] MF>
<B[1] PTN>
>.
S3F6: CASSETTE FOUND ACKNOWLEDGE (host -> reader)
The host acknowledges the cassette found message.
S3F6
<B[1] ACKC3>.