User's Manual

Table Of Contents
Product Manual - RFID Reader LF60C SoliD 105
Chapter 7
Operation
Parameter 44
(0x2C)
FixedMID
Defines the read, write and error behavior regarding the CarrierIDLength defined
in SEMI E99-0303.
0 Dynamic CID length (to ensure compatibility with older versions).
MID length is variable for writing to the tag.
Reading up to the first non-visible ASCII character.
1 Fixed CID length (to meet the new standard revision).
Length of MID in the tag must be the same as the reader settings. If
there is a non-visible ASCII character within the CID field, an error
occurs.
Default: 1
Parameter 45
(0x2D)
MIDFormat
Defines the physical format of the MID data in the transponder memory. Affects
the messages S18F9/F10 and S18F11/F12.
0 E99 standard format left aligned - meets the
requirement of the SEMI standard E99
Default: 0
Examples: MID string is '123456789ABC'
Parameter 45 = '0':
Tag memory:
Output string: '123456789ABC'
Page 2 9 A B C 0x00 0x00 0x00 0x0
0
Memory address 15 14 13 12 11 10 9 8
Page 1 1 2 3 4 5 6 7 8
Memory address 7 6 5 4 3 2 1 0