User's Manual

Table Of Contents
Product Manual - RFID Reader LF60C SoliD 103
Chapter 7
Operation
Parameter 37
(0x25)
MID area
This parameter defines the range of the MID.
'0' … '10' pages
Default: '2' - MID area = 2 pages = 16 bytes (depends on parameter 25).
Parameter 38
(0x26)
Test after software reset
This parameter enables/disables the initial test after a software reset.
0 No initial test after software reset
1 Initial test after software reset
Default: (0) No initial test after software reset
Parameter 40
(0x28)
Transponder load duration (write-mode)
The time required to load a transponder during a write process.
The default value (50 ms) should not be changed.
00 .. 255 ms
Default: (50) 50 ms
Parameter 41
(0x29)
Delay time between read cycles
The delay time between two reading cycles. It takes care of the reading module
lifetime.
To increase reading speed, set the delay time to zero.
1 .. 250 1 ms
Default: (10) 10 ms
IMPORTANT
See also parameters 42 - 45 and 99.