User's Manual

Table Of Contents
Product Manual - RFID Reader LF60C SoliD 102
Chapter 7
Operation
Parameter 33
(0x21)
Automatic antenna adjustment
The parameter defines the permitted causes for an antenna adjustment.
0 Automatic adjustment is not activated
1 Automatic adjustment only by DIP8
2 Automatic adjustment only by external command
3 Automatic adjustment by DIP8 or external command
Default: (3) automatic antenna adjustment by DIP8 or external command
Parameter 34
(0x22)
Sensor type for presence sensor
Type of sensor signal to start an automatic read.
0 Automatic read starts if sensor is covered
1 Automatic read starts if sensor is not covered
Default: (0) sensor is covered
Parameter 35
(0x23)
Special features
After a hardware reset, the reader offers an automatic read if the presence sensor
is covered.
bit 0: value 0: Effect auto read after reset, if sensor is covered
value 1: Effect no auto read after reset, if sensor is coverd (default)
bit 1: value 0: Effect a sensor triggered auto read (default)
value 1: Effect no sensor triggerd auto read
bit 2: Without function
bit 3: Without function
bit 4: The setting of the LEDs by S18F13 "SetLED" is prioritized
Default: 0x01 (0000 0001)
Parameter 36
(0x24)
DIP switch activation
Bits 0 to bit 4 define the behavior of DIP switches 8 down to 5. DIP switches 4
down to 1 have no function at this time.
bit0: DIP 8 for tuning is active in test mode
bit1: DIP 8 for tuning is active in normal mode
bit2: DIP 7 (activate test mode) activation
bit3: DIP 6 (type of test mode) activation
bit4: DIP 5 can be used for protocol change
Default: 0x1F (0001 1111)