User's Manual
Table Of Contents
- 1 Identification
- 2 Declaration of Conformity
- 3 General Instructions
- 4 Safety Instructions
- 5 Product Specifications
- 6 Installation
- 7 Operation
- 7.1 Operating personnel
- 7.2 Protocol change
- 7.3 Operation of the ASC-I1 protocol
- 7.3.1 Structure of the communication protocol
- 7.3.2 Package contents
- 7.3.3 Commands of protocol
- Commands host to reader
- Commands reader to host
- Message items
- X - Read data
- W - Write data
- R - Automatic read
- G - Request parameter value
- P - Set parameter
- N - Reset
- e - Error message
- H - Heartbeat
- V - Query software version
- L - Lock a page of the transponder
- I - Set tuning of the RF module
- J - Request tuning settings of RF module
- A - Sensor event
- 7.3.4 Parameters
- 7.3.5 Message examples
- 7.4 Operation of SECS/HSMS Protocol
- 7.4.1 Introduction
- 7.4.2 SECS-I implementation
- 7.4.3 HSMS option
- 7.4.4 HSMS implementation
- 7.4.5 SECS-II implementation
- 7.4.6 Parameters
- Parameter 0 (0x00)
- Parameter 1 (0x01)
- Parameter 2 (0x02)
- Parameter 3 (0x03)
- Parameter 4 (0x04)
- Parameter 5 (0x05)
- Parameter 6 (0x06)
- Parameter 7 (0x07)
- Parameter 8 (0x08)
- Parameter 9 (0x09)
- Parameter 11 (0x0B)
- Parameter 12 (0x0C)
- Parameter 20 (0x14)
- Parameter 22 (0x16)
- Parameter 23 (0x17)
- Parameter 24 (0x18)
- Parameter 25 (0x19)
- Parameter 26 (0x1A)
- Parameter 27 (0x1B)
- Parameter 29 (0x1D)
- Parameter 30 (0x1E)
- Parameter 31 (0x1F)
- Parameter 32 (0x20)
- Parameter 33 (0x21)
- Parameter 34 (0x22)
- Parameter 35 (0x23)
- Parameter 36 (0x24)
- Parameter 37 (0x25)
- Parameter 38 (0x26)
- Parameter 40 (0x28)
- Parameter 41 (0x29)
- Parameter 42 (0x2A)
- Parameter 43 (0x2B)
- Parameter 44 (0x2C)
- Parameter 45 (0x2D)
- Parameter 98 (0x62)
- Parameter 99 (0x63)
- 7.4.7 SEMI E99
- 7.4.8 Message details
- 7.4.9 HSMS message examples
- 7.4.10 SECS-I message examples
- 8 Service and Troubleshooting
- 9 Dismantling and Storage
- 10 Transport and Disposal
- 11 Accessories
Product Manual - RFID Reader LF60C SoliD 100
Chapter 7
Operation
Parameter 23
(0x17)
Triggered read frequency
If a read/write error occurs, the triggered read frequency defines the time
between two attempts to read or write a transponder; or the read frequency if
there is a triggered read (no polling).
2 .. 10 from 1/10 s
Default: (5) 500 ms
Parameter 24
(0x18)
r/w max repeat
Delay time for sensor signal to start a defined action.
0 .. 255
Default: 5
Parameter 25
(0x19)
Transponder type
This parameter defines the validity of the read transponder data.
00 ... Read and write TIRIS type
Each transponder page consists of 8 data bytes.
The validity of the data bytes is
checked by a 2 byte CRC checksum.
Default: 00
Parameter 26
(0x1A)
Sensor activity
The transponder reader offers the option of deactivating the connected sensor.
0 Sensor not activated
1 Sensor activated
Default: 1
Parameter 27
(0x1B)
Watchport for presence
Enables a message to the host if a cassette/FOUP is detected on the I/O port, or if
it is removed from the I/O port.
A sensor is required to use this option.
0 Report nothing
1 Report cassette/FOUP is removed
2 Report cassette/FOUP is detected
3 Report cassette/FOUP is detected and cassette is removed
Default: (3) Report cassette/FOUP is detected and removed