OPERATION 5
65
Transponder Reader LF60 Gen2 (SECS1-Protocol), Release 0.2
PAGEDATA
Format: B[9]
The cassette identifier that has been read or will be written. The
PAGEDATA corresponds to the value of a transponder page.
PAGEDATA [0] Corresponds to the page number. The value of
the page number is displayed in the data item
“PAGE_ID”.
PAGEDATA [1] The 8 byte (one page) of the transponder ID
are following.
PAGEDATA [8]
Where used: S3F7, S3F12, S3F13, S3F65
PM Information
Format: A[2]
Description: Preventive maintenance information
“NE” … Normal execution
“MR” … Maintenance required
Where used: S18F2, S18F4, S18F8, S18F10, S18F12, S18F14
PTN
Format: B[1]
Information about the state of up to two sensors and the initiator of the
message. The second sensor is not implemented yet!
For special applications, the reading process of the transponder reader
is triggered by two sensors. In this case, it is necessary to distinguish
between the two sensors. The initiator represents the number of the
sensor which has caused the message.
Default: only sensor 0 is defined!
bit 7 ........ bit 0
Initiator Sensor 1 Sensor 0
...
...