User's Manual

5 OPERATION
58
Transponder Reader LF60 Gen2 (SECS1-Protocol), Release 0.2
Parameter 36: DIP switch activation
Defines which DIP switch is active or not. Bit 1 to bit 4 correspond to
DIP switch 1 to 4. Bit 0 is not used at this moment.
0x0001 1110 : all DIP switches are active.
0x0000 0000 : all DIP switches are deactivated.
Default: 0x1E (0001 1110)
Parameter 37: MID area
This parameter defines the range of the MID.
‘0’ … ‘10’ pages
Default: ‘2’ – MID area = 2 pages = 16 bytes (depends on
parameter 25).
See also parameter 42 – 45 and 99.
Parameter 38: Test After Soft Reset
This parameter enables/disables the initial test after a software reset.
0 No initial test after software reset
1 Initial test after software reset
Default: (0) No initial test after software reset
Parameter 39: Not defined!
Parameter 40: transponder load duration (write-mode)
The time required to load a transponder during a write process.
The default value (50ms) should not be changed!
00 .. 255 ms
Default: (50) 50ms