User's Manual

OPERATION 5
53
Transponder Reader LF60 Gen2 (SECS1-Protocol), Release 0.2
Parameter 9: Heartbeattime
The readers offer the option of generating a regular heartbeat. This
means the reader sends a S1F1 message to the host in the defined
interval.
0 No heartbeat
1 … 255 10s (10s - 2550s)
Default: 0 no heartbeat
Parameter 10: Not defined!
Parameter 11: Reader-ID
The reader ID is a part of the device ID. In the message header, it
corresponds to the 7 LSB (last significant bits) of the “upper message
ID”.
00 .. 127
Default: 0x01
The LDN reader works simultaneously as a gateway and a reader
(CIDRW with integrated head). Therefore the reader ID is predefined
as 0x01. Of course, the ID can be changed within the valid scope.
Parameter 12: Head-ID
If you use a two-byte TARGETID, this parameter corresponds to
TARGETID.
00 .. 31
Default: 0x01
The head ID is predefined as 0x01. Of course, the ID can be changed
within the valid scope.